D01135020B

Contents

Updates ................................................................................................1
New functions ...................................................................................1

V1.20 additions ...........................................................................1
V1.11 additions ...........................................................................1

Maintenance items ..........................................................................1

V1.20 changes .............................................................................1
V1.11 changes .............................................................................3

Checking the firmware version ...................................................3
Firmware update procedures .......................................................3

Updates

Always use the most recent firmware for this unit.
Please visit the TASCAM website (http://tascam.com/) to 

check for the latest firmware.

New functions

V1.20 additions

A tape emulation mode has been added for use with 

 

an editor/synchronizer that supports the SONY P2 

protocol using the RS-422 connector.
Japanese folder and file names can now be displayed. 

 

Japanese input, however, is not supported by this unit.
Chase can now be turned ON and OFF via RS-232C.

 

The SONY P2 protocol REC command is now supported. 

 

The 

 

OK

/

CANCEL

 buttons in pop-up windows can now 

be operated using the Enter/Esc keys on an external 

keyboard.

NOTE

For details about these features, please see the "HS-8 

Firmware Update V1.20" document, which is also available 

from the TASCAM website.

V1.11 additions

Keyboards with USB interfaces can now be connected 

 

to the unit.
Synchronized playback when the input timecode and 

 

the project timecode differ is now possible. 

Maintenance items

V1.20 changes 

When using an external keyboard, some characters (

 

\ / 

: ; , • ? “ < > | ) that are not allowed to be used with FAT 

file system format disks could be input for file names. 

This has been fixed. 
On the 

 

MARK LIST INFO

 screen, if 

MANUAL MARK

 

was selected and 

DELETE

 executed, all the 

MANUAL 

MARK

 would not be deleted and one would remain. 

This has been fixed. 
On the 

 

SYNC T/C

 screen, even if the frequency was 

correct, 44.1kHz was not properly shown. This has been 

fixed.
When navigating the 

 

CREATE PROJECT

 screen, 

sometimes the 

CREATE PROJECT

 button would be 

unavailable, and the project could not be created. This 

has been fixed.
When the 

 

TC Chase

 on the 

SYNC

 page of the 

SYNC 

T/C

 screen was 

ON

, if the external timecode was 

momentarily lost and then recovered after a jump, a 

playback synchronization error of 200–400 μs would 

occur. This has been fixed. 
When the 

 

TC Rechase

 setting on the 

SYNC

 page of 

the 

SYNC T/C

 screen was 

OFF

, the SONY P2 protocol 

time code was not updated during TC Chase. This has 

been fixed.
Immediately after stopping recording, the time code 

 

time for the start of the recording was output as the 

SONY P2 protocol time code. This has been fixed. 
The precision of the start time stamped in files has 

 

been increased when recording with 

TC GEN MODE

 

on the 

SETUP

 page of the 

SYNC T/C

 screen set to 

REGEN

 or 

JAM SYNC

.

iXML chunks were not always written with the correct 

 

size. This has been fixed.
Negative value could be mistakenly written in iXML 

 

time stamps. This has been fixed.
CF cards of 2 GB or less are now formatted as FAT16. 

 

Some mark point information could not be read. This 

 

has been fixed. 
If the file size of a recording exceeded 2 GB and there 

 

was less than one minute of remaining space on the CF 

card, a 

Record Error

 would occur and the part over 

2 GB would be recorded with incorrect audio data. This 

has been fixed.
If a link was turned ON when only the even numbered 

 

channel had solo or input monitoring enabled, the link 

might not be correctly activated. This has been fixed.
When loading a folder or take from another project, 

 

the setting file for the current project before being 

changed was not updated. This has been fixed.
Sometimes pop-up messages would not disappear. 

 

This has been fixed.