TASCAM HS-2000
105
11 – Internal settings
T/C page
Make settings related to timecode on this page.
Free Run mode
Jam Sync (or Free Once)
STATUS
This shows the timecode generator mode of the unit
and the timecode frame type of the currently loaded
project.
GENERATOR
The top line shows the current timecode generator
time. The bottom line shows the user bits (UB).
Touch the GENERATOR item
EDIT
button or the user
bits (UB) number area to open the
T/C USER BITS
screen.
When the timecode generator is in Free Run mode,
touch the
RESTART
button to reset the timecode of
the timecode generator to the start time.
TC IN
The top line shows the time of the input timecode and
the frame type. The bottom line shows the user bits
(UB) of the input timecode.
In Free Run mode, touch the
CAPTURE
button
to capture the current timecode and set it as the
timecode of the timecode generator.
If the timecode generator mode is set to Free Once or
Jam Sync, the capture status (WAITING) indicator lights
green when waiting for timecode, and it turns off after
timecode is captured.
START TIME
When you touch the GENERATOR item
RESTART
button, the time when the timecode restarts is shown.
Touch the START TIME item
EDIT
button or the START
TIME display area to open the
START TIME
screen.
SETUP page (Sync and timecode
settings)
Make settings related to the timecode generator on this
page.
STATUS
This area shows the currently loaded project’s
timecode frame type.
TC GEN MODE
Use the buttons to set the timecode generator mode.
FREE RUN:
The timecode generator runs on its own.
FREE ONCE:
The unit’s timecode generator captures the received
timecode once, and then runs independently.
TIME OF DAY:
If you conduct any of the following operations, the
timecode value is captured from the unit’s internal
date/time clock and the unit timecode generator
runs on its own.
Turn the power on
•
Set TC GEN MODE to this mode
•
Reset the internal clock
•
JAM SYNC:
When timecode is received, the unit synchronizes to
it. If timecode input is interrupted, the unit timecode
generator runs on its own.
REGEN:
The unit synchronizes to the received timecode.
REC RUN (default):
The timecode generator only functions during
recording. At all other times, the timecode generator
stops.
Frame Type
Set the timecode frame type of the currently loaded
project.
Setting buttons: 23.976F, 24F, 25F, 29.97DF (default),
29.97ND, 30DF, 30ND