3. MAINTENANCE
Steinle Filter Press Pump Series
28
3.6.
FP/FH 40-80 – Disassembly of the pump
The numbers put in brackets, refer to the part numbers in the spare part drawings and spare part
lists in chapter chapter 4
Błąd! Wynik nieprawidłowy dla tabeli.
.
3.6.1.
Before the disassembly procedure
Be sure to drain all liquid from the pump. Cleanse or neutralize the pump thoroughly.
Disconnect the air and the power supply and then the suction and discharge connections.
3.6.2.
Disassembly procedure
Fig. 3.7.1
Remove the Ventilation screw [62] for the hydraulic
liquid. Open the drainage ball valve [80] for the
hydraulic liquid and collect the liquid.
Fig. 3.7.2
Unscrew and remove mufflers [34].
Fig. 3.7.3a
Disconnect two air hoses [33] connecting the outlet
manifold [3] to the housings [1].
Fig. 3.7.3b
Unscrew and remove two hex screws, nuts and
washers [65] connecting the control unit [35] to the
housings [1].