3. MAINTENANCE
Steinle Filter Press Pump Series
23
3.5.
FP/FH 25 – Disassembly of the pump
The numbers put in brackets, refer to the part numbers in the spare part drawings and spare part
lists in chapter 4
Błąd! Wynik nieprawidłowy dla tabeli.
.
3.5.1.
Before the disassembly procedure
Be sure to drain all liquid from the pump. Cleanse or neutralize the pump thoroughly.
Disconnect the air and the power supply and then the suction and discharge connections.
3.5.2.
Disassembly procedure
Fig. 3.6.1
Open the drainage ball valve [80] for the hydraulic
liquid and collect the liquid. Remove the
Ventilation screw [62] for the hydraulic liquid.
Fig. 3.6.2
Unscrew and remove mufflers [34].
Fig. 3.6.3a
Disconnect two air hoses [33] connecting the
outlet manifold [3] to the housings [1].
Fig. 3.6.3b
Unscrew and remove two hex screws [61] connecting
the control unit [35] to the housings [1].