5. Maintenance and inspection
IOM manual
–
SPT series
26
5.5.4.
Reassembly procedure
1. For reassembly procedure follow the disassembly procedure in reverse sequence.
Nevertheless there are a few things that you have to remember in order to assemble
the pump correctly.
NOTICE:
➢
The gaskets and O-rings must be replaced with new ones. Also replace any parts
that are worn or damaged.
➢
After complete reassemble, keep in mind to pour the specified amount of oil into
the pump.
2. Wipe and degrease the mechanical seal sealing faces. Lubricate the outer
circumference of the mechanical seal to facilitate insertion.
NOTICE:
➢
For further details on how to install the mechanical seal, refer to the "Mechanical
seal assembly procedure" that comes with the mechanical seal that is sold
separately as a spare part.
➢
For cleaning use dust-free material e.g. blue towel TORK 1230081.
3. After complete reassemble check that the impeller rotates smoothly and that it does
not come in contact with the suction cover.
4. To make sure that the pump operates normally, perform a trial operation before
placing the pump back into service.
5.5.5.
Wearing parts replacement condition
Part name
Pump model
Replacement condition
Mechanical seal
All
Lubrication oil discoloured
Gasket and O-ring
All
Each disassembly or inspection
5.6.
How to order spare parts
When ordering spare parts for Tapflo pumps, let us know what is the
model
and
serial number
from the pump nameplate. Then just indicate the part numbers from the spare parts list and
quantity of each item.