3. MAINTENANCE
IOM manual active pulsation dampeners
14
3.4.
Location of faults
PROBLEM
POSSIBLE FAULT
POSSIBLE SOLUTION
The dampener does not
work
The air pressure is to low
Check if set pressure equals set pressure for the
pump
The air connection is blocked
Check / clean air supply connection
Muffler is blocked
Check / clean / replace muffler
Dirt in the dampener chamber
Remove debris from the chambers
Diaphragm breakdown
Replace diaphragm
Liquid leaks from the
dampener
Screws on the housing not properly
tightened
Check tightening torques of the screws
Damaged diaphragm
Check / replace diaphragms
Tension / stress form the installation
Adjust installation, eliminate stress, provide
separate support for dampener
Liquid comes out of the
muffler
Diaphragm breakdown
Replace diaphragm
Continuous air leakage
through muffler
Air leakage through diaphragm shaft
Replace dampener block seal or/and diaphragm
shaft
Diaphragm breakdown
Wrong selection of material
Contact us for information on material selection
Too high pressure in the installation
Use pressure regulator for protection
Too high pressure on suction side
Make sure there is pressure balance between the
air and liquid side of the diaphragm