6.
DATA
IOM manual CTV vertical centrifugal pumps
34
6.5.
Permitted loads on inlet and outlet
We recommend not to exceed the following loads and forces reacting on the inlet and
outlet.
CTV 25
–
PP & PVDF
Direction
Load [N]
(inlet/outlet)
Moment of force
(inlet/outlet) [Nm]
X
23
4
Y
23
4
Z
23
4
CTP 32
–
PP & PVDF
Direction
Load [N]
(inlet/outlet)
Moment of force
(inlet/outlet) [Nm]
X
33
6
Y
33
6
Z
33
6
CTV 20
–
SS
Direction
Load [N]
(inlet/outlet)
Moment of force
(inlet/outlet) [Nm]
X
70
6
Y
100
6
Z
70
6
CTV 25
–
SS
Direction
Load [N]
(inlet/outlet)
Moment of force
(inlet/outlet) [Nm]
X
80
8
Y
120
8
Z
80
8
CTV 40
–
SS
Direction
Load [N]
(inlet/outlet)
Moment of force
(inlet/outlet) [Nm]
X
100
10
Y
150
10
Z
100
10