6.
DATA
IOM manual CTV vertical centrifugal pumps
31
6.2.
Dimensions and data
–
PP & PVDF pumps
Dimensions in mm (
inch
)
General dimensions only, ask us for detailed drawings. Changes reserved without notice.
DIMENSION CTV 25 CTV 32
A
285
11.22
B
200
7.87
D*
0,55 kW
196
7.72
0.75 kW
÷
2.2 kW
220
8.66
E
85
3.35
F
56
2.2
G
95
3.74
H (BSP)
1 ½”
1 ½
I*
0,55 kW
213
8.39
0.75 kW
÷
2.2 kW
319
12.56
J
25
0.98
K
413
16.26
L
123
126
4.84
4.96
M
60
2.36
N (BSP)
1”
1 ¼”
1
1 ¼
* Dimension may vary depending on motor brand
Pump model CTV
25-9
25-10
25-11
25-11.5
32-8.5
32-10
32-12.5
Max capacity [m
3
/h]
12
14
15.5
18
13
17
19
Max head [m]
11
14
17
18
9
14
20
Motor power [kW]
0.55
0.75
1.1
1.5
1.1
1.5
2.2
Outlet dimension [BSP]
1”
1”
1”
1”
1 ¼”
1 ¼”
1 ¼”
Impeller torque [Nm]
20
20
20
20
20
20
20
Weight [kg]*
11.7/14
12.7/15.3
13.4/16.4
16.1/18.3
13.7/16.8
16/18.1
17.6/19.9
Motor data
3-phase, 2-pole (2900 rpm), 380-420 VAC, 50 Hz, IP55
Max solids size [mm]
6 mm
Max temperature
Pump in PP:
70°C
; Pump in PVDF:
100°C
* PP/PVDF