background image

F o l l o w i n g   i n f o r m a t i o n   i s   o n l y  
f o r   E U - m e m b e r   s t a t e s :

 

M a i n t e n a n c e  

 
In the event of heater failure or for spare parts or advice, please contact the 
manufacturer in the first instance. 
 

Disconnect  from  the  mains  before  commencing  any  maintenance  procedure  including 
cleaning. 

To  ensure  optimum  heat  effectiveness,  periodically  it  is  recommended  the  guards  and 
lamps should be removed to gain access to the reflector, which should be wiped with a lint-
free cloth before reassembling. Please take care not to handle the lamp with bare hands. 

© Tansun Limited 2010                         Part No. 042028                                    Issue. 4 

M o u n t i n g  

 

The heater must be mounted in such a way that the halogen lamp does not slant more than 
4° from the horizontal, when viewed from the front. 

The heater is suitable for installation only on a normally non-flammable surface. Observe the 
minimum safe distance between the heater body and inflammable surfaces when mounting. 

Do not position the heater near to furniture or curtains as this could present a fire hazard. 

Refer to Table 1 for the recommended mounting height for the heater. 

Please refer to Table 1 for the recommended installation height of the heater. 

Keep out of the reach of children. 

 
1. Separate the heater from the mounting bracket by loosening the two nuts at the rear of the 
heater. 
 
2. Securely fasten the bracket to the mounting surface using the fixing holes in the bracket. 
 
3. Replace the heater on the bracket using the nut and bolt supplied and fix in the required 
angular position by tightening the fixing bolt on the bracket. See Figs 2 and 3. 
 

Always isolate the heater from the mains supply when adjusting the angular position. 

Fig. 2 

Fig. 3 

R e p l a c i n g   t h e   L a m p  

 
1. Disconnect from the power supply and remove the heater from wall fixings before attempt-
ing to replace any lamp. 

 

2. If a guard is fitted, remove it by flexing one end. 

 

3. Remove the screws from the end extrusion(s) and fascia panels (fitted between lamps on 
large models) adjacent to the failed lamp (see Fig.4). 

 

4. Remove the panels to expose the lamp connections (see Fig.5). 

 

5. Disconnect lamp leads from terminal plates, and remove lamp retaining clips (see Fig.6). 

 

6. Slide the lamp out through the extrusion. 

 

7. Fit a new lamp, taking care not to mark the reflector or handle the lamp (see caution note). 

 

8. Replace lamp retaining clips and connect the new lamp leads to the terminal plates, en-
suring live/neutral leads are also reconnected. 

 

9. Replace the end extrusion(s) and fascia panels securely, using the fixings previously 
removed and refit the guard. 
 

Caution. 

Do not handle lamp with bare hands. 

Remove finger marks with a soft cloth and methylated spirit or rubbing alcohol. Finger marks 
will burn into the quartz glass causing premature lamp failure. 
 

Please note: 

Apollo outer casing can reach high 

temperatures. 

Fig. 4 

Fig. 5 

Fig. 6 

Plan 

View 

Side View 

The use of this symbol indicates that this product may not be treated as household waste. By ensuring this product is 
disposed  of  correctly,  you  will  help  prevent  potential  negative  consequences  for  the  environment  and  human  health, 
which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about 
recycling of this product, please contact your local council, your household waste disposal service or the shop where 
you purchased the product.

 

Reference Manual 

Apollo 

 

UK & EUROPEAN MODELS 

Spectrum House, Unit 1 Ridgacre Road, West Bromwich, 

West Midlands, B71 1BW, England. 

Tel: +44 (0)121 580 6200   -   Fax: +44 (0)121 580 6222 

Email: [email protected]   -   Website: www.tansun.com 