FAULT CONDITION
>>
"Passed" or "arm turned" information is not received after passing
Reason:
Connections may be broken or incorrect. The 'XL9 terminal' of the control card may be
defective.
Solution:
The connections should be checked manually and visually. If the control card is
defective, it should be replaced.
>>
The turnstile allows a continuous pass to one direction.
Reason:
It may be running in one-way free mode. The solenoid cable or spring may be displaced.
Solution:
The "3rd" and "4th" dip switch positions of the control card should be checked. If there
is a displaced spring or cable, it should be replaced. If it doesn't work, it should be replaced.
>>
The turnstile works properly with all its functions, but the guiding LEDs do not turn on.
Reason:
LED cards or LED cables may be defective. The motherboard may be defective.
Solution:
If the LED card is defective, it should be replaced. If the LED cable is defective, it
should be replaced. If the card is defective, it should be replaced.