Tannoy CVS6 Installation Manual Download Page 1

6481 0487

Tannoy has a policy of continuous improvement and this specification sheet provides the latest information at the time of printing.

All specifications may be subject to further change.  Please contact the Tannoy website for the latest information.

CVS 4

CVS 6  

CVS 8  

I N S T A L L A T I O N   M A N U A L

CVS 4 TEMPLATE CUTOUT SIZE: 180mm

CVS 6 TEMPLATE CUTOUT SIZE: 250mm

 

A

T

CVS 8 TEMPLATE CUTOUT SIZE: 320mm 

REVISION DATE: 03 March 2011

  

;HUUV`°+PYLJ[°<2
;*.0°96>°ZHSLZ

°

;!°° °°°  

,!°LUX\PYPLZ'[HUUV`JVT

;!°°

°

,!°PUMV'[JNYV\WPU[LYUH[PVUHSJVT

;*.((TLYPJHZZHSLZ

;!°°° °°

,!°PUMV'[JNYV\WHTLYPJHZJVT

;HUUV`°4PKKSL°,HZ[

;!° °

,!°LUX\PYPLZ'[HUUV`JVT

;HUUV`°HKVW[Z°H°WVSPJ`°VM°JVU[PU\V\ZPTWYV]LTLU[HUK° WYVK\J[°ZWLJPMPJH[PVU° PZ°Z\IQLJ[°[VJOHUNL

°

Summary of Contents for CVS6

Page 1: ...CVS 4 CVS 6 CVS 8 I N S T A L L A T I O N M A N U A L CVS 4 TEMPLATE CUTOUT SIZE 180mm CVS 6 TEMPLATE CUTOUT SIZE 250mm A T CVS 8 TEMPLATE CUTOUT SIZE 320mm ...

Page 2: ...INGS MECHANICAL INSTALLATION GUIDE FOR SHEET ROCK CEILINGS MECHANICAL INSTALLATION INSTRUCTIONS FOR OPTIONAL PLASTER RING WIRING AND SETTING UP DIMENSIONS CVS 4 DIMENSIONS CVS 6 DIMENSIONS TECHNICAL SPECIFICATIONS WARRANTY DECLARATION OF CONFORMITY 6 1 6 2 6 3 7 8 8 1 8 2 9 11 12 CVS 8 DIMENSIONS 8 3 PAINTING 10 PRODUCT FEATURE IDENTIFICATION 4 ...

Page 3: ...y event of any damage would you please notify your dealer immediately and retain your shipping carton as your dealer may ask you to return the faulty unit to them for inspection Each CVS loudspeaker is packed in pairs and provided with the following accessories as standard C Ring tile bridge kit grille cut out template and paint mask A plaster mud ring is also available as an optional extra 3 SAFE...

Page 4: ...CATION CVS 4 CVS 6 CVS 8 Conduit Cable Clamp Mounting Wings Safety Tab Tuning Ports Rotary Switch Screws for mounting wings Tuning Ports Rotary Switch Screws for mounting wings Tuning Ports Rotary Switch Screws for mounting wings Conduit Cable Clamp Mounting Wings Safety Tab ...

Page 5: ...SORIES Standard Accessories C Ring Tile bridge kit Note A tile bridge kit must always be used when installing into suspended ceiling tiles Grille Cut out template Paint Mask Optional Accessories Plaster Mud Ring ...

Page 6: ...d tile bridge on top of the ceiling panel aligning the C ring over the hole and screw the C ring to the tile bridge using the fixings provided 3 Cut out the hole in the ceiling tile using a circular saw or pad saw 2 Remove the ceiling tile from its frame and place it on a flat surface Mark the cut out area on the ceiling tile by tracing around the template provided 1 Go to section 7 for instructio...

Page 7: ...nd the template provided 1 7 Connect a Secondary Support Line to safety tab Some construction codes require use of this secondary support point which should connect to a separate secure support point using a suitable support line Consult construction codes in your region 5 Insert grille by pushing it onto the speaker 6 Slide the speaker assembly through the hole and turn the screws to extend the m...

Page 8: ...lings Cut out the hole in the ceiling using a circular saw or pad saw 3 5 Go to section 7 for instructions on wiring then return to point 5 below 4 Connect a Secondary Support Line to safety tab Some construction codes require use of this secondary support point which should connect to a separate secure support point using a suitable support line Consult construction codes in your region 6 Slide t...

Page 9: ...whether you wish to use the speaker in a low impedance or distributed line application 3 THE SPEAKER IS SUPPLIED IN LOW IMPEDANCE MODE NEVER CONNECT THE SPEAKER TO A 70 100 VOLT AMPLIFIER WHILE IT IS SET FOR LOW IMPEDANCE The CVS 4 is fitted with a 30W transformer When used in distributed line systems the transformer can be tapped at 30W 15W and 7 5W with an additional 3 75W tapping for 70 7V line...

Page 10: ...10 8 1 CVS 4 DIMENSIONS CVS 4 TEMPLATE CUTOUT SIZE 180mm ø174 8 6 88 14 7 0 58 202 5 7 97 214 9 8 46 ø213 0 8 39 ...

Page 11: ...11 8 2 CVS 6 DIMENSIONS CVS 6 TEMPLATE CUTOUT SIZE 250mm ø244 6 9 63 246 5 9 70 15 9 0 63 258 5 10 18 ø279 6 11 01 ...

Page 12: ...12 8 3 CVS 8 DIMENSIONS CVS 8 TEMPLATE CUTOUT SIZE 320mm 355 6 14 00 19 6 0 77 251 0 9 88 264 0 10 39 315 2 12 41 ...

Page 13: ...W 3 75W OFF low impedance operation 30W 15W 7 5W OFF low impedance operation 2nd Harmonic 3rd Harmonic 0 231 0 112 0 229 0 253 0 163 0 025 2nd Harmonic 3rd Harmonic 0 99 0 169 0 816 0 323 0 444 0 027 2 7kHz Transducers Low Frequency High Frequency 100mm 4 00 Mineral Loaded 19mm 0 75 Physical Enclosure Back can Baffle Grille Safety Features Clamping Design Back Can Options Cable Entry Options Conne...

Page 14: ... OFF low impedance operation 60W 30W 15W OFF low impedance operation 2nd Harmonic 3rd Harmonic 0 439 0 140 0 396 0 458 0 235 0 023 2nd Harmonic 3rd Harmonic 1 16 0 214 1 014 0 685 0 944 0 047 2 5kHz Transducers Low Frequency High Frequency 150mm 6 00 Mineral Loaded polypropylene ICT 19mm 0 75 Physical Enclosure Back can Baffle Grille Safety Features Clamping Design Back Can Cable Entry Options Con...

Page 15: ... OFF low impedance operation 60W 30W 15W OFF low impedance operation 0 33 0 25 0 15 0 63 0 12 0 03 1 10 0 25 0 55 0 70 0 52 0 03 6kHz Transducers Low Frequency High Frequency Coaxial 200 mm 8 00 mineral loaded cone material 19mm 0 75 Physical Enclosure Back can Baffle Grille Safety Features Clamping Design Back Can Cable Entry Options Connectors Safety Agency Ratings pending Hole Cutout Diameter D...

Page 16: ...ed by a 5 year warranty from the date of manufacture subject to the absence of misuse overload or accidental damage Claims will not be considered if the serial number has been altered or removed Work under warranty should only be carried out by a Tannoy Professional dealer or service agent This warranty in no way affects your statutory rights For further information please contact your dealer or d...

Page 17: ...nications equipment and other apparatus to operate as intended and the apparatus has an adequate level of intrinsic immunity to electromagnetic disturbance to enable operation as specified and intended This equipment conforms to the requirements of the EMC Directive 89 336 EEC amended by 92 31 EEC and the requirements of the Low Voltage Directive 73 23 EEC amended by 93 68 EEC Details of the Appar...

Page 18: ...ns may be subject to further change Please contact the Tannoy website for the latest information REVISION DATE 03 March 2011 HUUV PYLJ 2 0 96 ZHSLZ LUX PYPLZ HUUV JVT PUMV JNYV W PU LYUH PVUHS JVT TLYPJHZ ZHSLZ PUMV JNYV W HTLYPJHZ JVT HUUV 4PKKSL HZ LUX PYPLZ HUUV JVT HUUV HKVW Z H WVSPJ VM JVU PU V Z PTWYV LTLU HUK WYVK J ZWLJPMPJH PVU PZ Z IQLJ V JOHUNL ...