background image

 

 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instruction Manual

Always adhere to all the instructions described below.
This is a prerequisite for installing and putting into use
this extremely modern and environmentally friendly
electrochemical piece of equipment in the most effective
and safest way possible. We strongly suggest that you ask 
an authorized dealer to install this equipment, check
it annually and replace the cellheart.

Always provide airflow!
Only maintenance: 
Clean and descale the electrolytic 
cellheart with (cleaning) vinegar or citric acid once 
per  2 to 4 weeks. See 

www.tank-o3.com

 “Cleaning-tips”

The system is suitable for use in both plastic and
stainless steel tanks but NOT in metal and aluminium
tanks!
Never use in combination with additives.

Why choose 

Tank

-O

3

?

And what is it exactly?

Those who regularly travel by camper, boat, caravan, tiny 
house etc. will - without doubt - sometimes wonder about 
the quality of drinking water in the clean water tank!
Consumption of drink water is not a problem, however.
The water is clean and potable.
But what about the development of biofilm, legionella,
algae, bacteria, viruses and germs in your tank when
no water is used for a long time? Particularly when you
prefer travelling to warm regions, the development of
microorganisms is not just imaginary.

Of course you have the option to counteract this
development by using all kinds of chemical agents. 
However, that is not desirable from an environmental 
point of view and it also leaves an unwanted taste and 
odour. Besides, it is a cumbersome and time consuming 
job and, therefore, it is often “forgotten”. Even if the 
water has been left in the tank for several weeks or even
months!

Tank

-O

3

 is the system that solves this difficult problem. 

From now on, you are assured of always having a biofilm-free, 
clean water tank with clean and safe water on board your 
camper, boat, caravan, tiny house etc.

Results of 

Tank

-O

3

Safe water, legionella prevention 
and always a clean water tank!

Tank

-O

3

 is an environmentally friendly system that

renders all biofilm, bacteria, germs, viruses, fungi,
algae, spores, legionella etc. in the water itself
harmless and, this is truly unique: throughout the
tank, from top to bottom and from left to right. 
Your tank is absolutely biofilm-free!

Tank

-O

3

  produces small amounts of ozone gas to 

disinfect the water tank through electrolysis.
Ozone gas is produced by converting oxygen, (O2) 
that is naturally present in water, to ozone (O3). 
In that way, the treated water also becomes “fuel’. 
Adding chemicals or harmful additives is not necessary. 
The amount of ozone gas 

Tank

-O

3

 produces, is so 

minimal that it is not harmful to health and does not 
endanger the environment. 
An important condition, however, is that the tank is
bled properly
. Often, some bleed air is already
present because of air flow in the tank, necessary
for topping up water. If this is not the case, a
separate bleed air system, e.g. an air release valve,
must be installed!

Tank

-O

3

 works on a safe, minimum low voltage, in

contrast to ozone generators or UV equipment which
all work on high voltage! With a tank capacity of 
100/150 liters, the cell current is set to only 50 mA.
If the tank capacity is smaller, the cell current will be
proportionally lower (about 30 mA). 
With a tank capacity of more than 150 liters, we 
recommend that you install 2 or more systems in the 
tank, in order to ensure that ozone gas is spread 
throughout the tank.

Because ozone gas only has a maximum lifespan of
25 minutes, depending on water temperature and
contamination of both tank and water, the distribution
of ozone in the tank water is of vital importance. 
As a result, the effect of ozone gas is optimized, leading 
to proper water treatment. A major additional advantage
of the gaseous form of ozone is that the tank is kept
completely clean, not only in the water part but also in 
the empty part (above water level, so also the top), and 
nothing else can clean both tank and water in such way, 
making it truly unique!

 
 

 

 

The carefree system for clean and safe 
water in a tank that is always spotlessly
clean!

Installation manual 

Parts of the 

Tank

-O

3

 system:

Part A  : 1 pc. Brass lid entry 
Part B  : 2 pcs. John Guest insert 12 mm - 3/8 thread 
Part C  : 1 pc. Hose, 30 cm long, Ø 12 mm (on request also in 
 

  other lengths) 

Part D  : 1 pc. Digital flow controller hxlxw: 30x90x36 mm 
Part E  : 1 pc. Electrolysis cell complete with cell nucleus 
Part F  : 1 pc. Connection cable with fuse to 12V or 24V point 
 

  (black / white is + (pos) / black is - (min) 

Part G  : 1 pc. Connection cable with round plug to electrolysis cell
  

  (black / white is + (pos) / black is - ( min) 

Part H  : 2 pcs. EPDM O-ring Ø 12 mm 
Part I  : 2 pcs. Green connection plugs 
Part J  : 7 cm Velcro self-adhesive 
Part K  : 1 pc. Awl 

       Drill a hole of Ø 16 mm in the tank 
lid with a spiral or woodspeed drill, 
preferably in the lid to make cleaning 
the cellheart as easy as possible. You 
can also choose to place an extra tank 
feed-through Ø 60 mm in which the 
above then can be carried out. 

       Make the hose (C) to length, 
this means shorten the hose to the 
maximum height inside the tank, i.e. 
from the bottom of the tank to the 
bottom of the lid, minus 6 cm

       Screw the brass cover lead-through 
(A) with the longest thread into the 
cover. The already placed piece of plastic 
hose in the top of the brass cover lead-
through prevents the connecting cable 
from rubbing through. 

       Bring 1 pc. O-ring (H) on the 
inside of the lid around the brass lid 
feedthrough (A) and tighten the John 
Guest insert bush (B) onto the brass lid 
feedthrough (A).

       Now first install the green 
connecting plug (I) on the connecting 
cable (G). Now run the connecting cable 
(G) with the round plug first through 
the brass cover hole (A), through the 
John Guest insert (B) and through the 
custom-made hose (C). 
See “Connecting the power wires to the    
          green plug”

      Then press the hose (C) firmly into 
the John Guest insert (B) on the bottom 
of the lid.

CWR Systems B.V.
Albardastraat 61
5344 HB Oss (NL)

      Now pass the plug and connecting wire (G) through the 
lower John Guest insert (B) and put the black O-ring (H) 
around the ozone cell (E) on the side where the plug is to be 
inserted. Now insert the plug into the ozone cell (E). 
Finally, screw the ozone cell (E) tightly into the bottom John 
Guest insert (B) and press it extra firmly onto the hose (C).

      Now mount the green connection plug (I) on connection 
cable (F) and on the other side mount the enclosed fuse on 
the black / white + (pos) wire. Connect the power wire from 
the 12 / 24V continuous power point to the Tank-O3 digital 
flow controller (D). Now the green LED lights up, the system 
works! The red LED may also light up at first moment of 
connection, this may take a few minutes. When only the 
green LED is lit, the Tank-O3 system is fully and correctly in 
operation.

Other information: 
Recommended mA: minimum 50mA for tanks up to approx. 
150 liters, may be lower (min. 30 mA) for smaller tanks! 

With the supplied piece of self-adhesive Velcro (J) you can 
attach the flow controller. 

The awl (K) is useful when connecting the connecting wires 
to the green connecting plugs and when replacing the cell 
core. 

- For information and questions: 

www.tank-o3.com

Assembling the 

Tank

-O

3

 system:

see 

www.tank-o3.com

”Instruction-manual” for Instruction 

video

Tank

-O

is part of

 

Summary of Contents for Tank-O3 System

Page 1: ... and always a clean water tank Tank O3 is an environmentally friendly system that renders all biofilm bacteria germs viruses fungi algae spores legionella etc in the water itself harmless and this is truly unique throughout the tank from top to bottom and from left to right Your tank is absolutely biofilm free Tank O3 produces small amounts of ozone gas to disinfect the water tank through electrol...

Page 2: ...50 mA It is also important to ensure proper air flow both in and out This is already naturally present in combination with the tank filler hole From now on your clean water tank and water leaves you completely carefree Congratulations The Tank O3 flow controller Explanation of the indications on the flow controller LED light Meaning What you can do Green Power System in use Green Red Short circuit...

Page 3: ... the electrolytic cell and press the John Guest insert firmly back onto the hose First check whether the hose remains firmly clamped in the John Guest insert Finally screw the lid with the hose and electrolytic cell back into the tank The electrolytic current may disrupt the water tank level indicator There are 2 solutions By placing a DC Convertor this problem will be solved Ask your dealer or co...

Page 4: ... I on the connecting cable G Now run the connecting cable G with the round plug first through the brass cover hole A through the John Guest insert B and through the custom made hose C See Connecting the power wires to the green plug Then press the hose C firmly into the John Guest insert B on the bottom of the lid CWR Systems B V Albardastraat 61 5344 HB Oss NL Now pass the plug and connecting wir...

Reviews: