Tanita BREATH ALERT Manual Download Page 1

2

1

4

3

About the BreathAlert

Replacing Batteries

The LCD display will flash a Battery
Icon to indicate that the batteries are
low. When this occurs, replace both
AAA type dry batteries together.

BreathAlert comes with trial batteries installed; their service life
will be short. Replacement batteries will last for about one year if
the unit is used approximately once every day. 

Note: If you don’t intend to use the product for a long period of time,
it’s advisable to remove the batteries. 

Handling Tips

• Don’t disassemble the unit.

• Clean occasionally by wiping with a soft cloth; don’t use water,

soap, paint thinner, etc. 

• Don’t apply pressure or subject the unit to vibration.

• Store in a place free from scents or odors. If you carry the

product in a cosmetic bag, for example, perfume or cosmetic
scents may adhere to the product. 

• Store in a place free from humidity, direct sunlight, and dust.

• Don’t store near a heating system.

Troubleshooting

If nothing appears on the LCD display after pushing the 
power button . . .
• Check to see that the batteries are correctly installed and no

dust has accumulated on them. Reposition clean batteries as
necessary. If the batteries are low, replace them.

If the readings are different each time . . .
• Move away from wind or strong environmental odors or scents.

If the head icon appears, but the breath odor level does not
appear on the LCD display . . .
• Reset the unit by gently waving it 4–5 times. Move away from

wind or strong environmental odors or scents.

If your breath odor level is higher than expected . . .
• Reset the unit by gently waving it 4–5 times. Make sure you wait

10 minutes after brushing your teeth before taking a reading.

If your breath odor level is lower than expected . . .
• Move away from wind or strong environmental odors or

scents. Make sure you wait until the display shows the word
“Start” before taking a reading. Hold the product about 1/2" 
(1 cm) away from your mouth. 

Product Limited Warranty*

Not Valid Without Proof of Purchase

Your Tanita product is warranted to the original consumer only, for one 
(1) year, to be free from defects in materials and workmanship under normal
use. This product is designed 

for Personal use only

. Tanita Corporation

of America reserves the right to nullify the warranty agreement should the
product be used in a commercial environment. This warranty is void if the
product has been tampered with or mistreated, or if the defect is related to
servicing or parts not supplied by us. Our obligation under this warranty is
limited solely to the charge of repairing the product, plus the cost of parts
or, at the option of Tanita, replacing the product with an equivalent model.
There are no express or implied warranties except as listed above.

Tanita

is not liable for incidental or consequential damages for failure
or malfunction of the product and any recovery may not be
greater than the purchase price paid for this product.

Some states

do not allow limitation on how long an implied warranty lasts, or the exclu-
sion or limitation of incidental or consequential damages, so the above lim-
itations may not apply to you. This warranty gives you specific legal rights
and you may also have other rights which vary from state to state. 

No per-

son is authorized to change the terms of this warranty.

If Product Is Defective or Needs Repair

Do not return this product to the place of purchase; doing so may delay the
processing of your warranty claim.

Call Tanita at 1-800-TANITA-8 to receive a Return Authorization Number
before returning this product. 

Proof of purchase must accompany

the product.

Because of possible loss, we recommend insuring your

product, return receipt requested, when using the mail. If you do not
receive a receipt within a reasonable time, start a tracer through the origi-
nating post office. It is important that you pack the product carefully prior
to shipment to prevent damage in transit and that you include a letter
describing in detail the specific condition requiring adjustment or repair. 

After Warranty Repairs

Please call Tanita at 1-800-TANITA-8 (USA and Canada only).

Please complete the following information and retain for your records.

Model: 

BreathAlert (HC201E)

Date Purchased:        /         /

Purchased From:

Address:

* Customers from the United Kingdom should use a separate

warranty, and contact Tanita’s office in the UK. Please see
separate warranty for the UK for further details.

Getting Started

How to Measure Breath Odor

Before use

The batteries are already installed.
To activate the unit, simply remove
the strip on the positive polarity. 

Taking Readings

1. Wave the unit gently in the air

4–5 times. This will remove any
odors or moisture left in the
product.

2. Turn the unit on by pushing 

the power button. It will beep 
in response. 

3. The Odor Symbol will appear and

count down from 3–1. When the
word “Start” is displayed, breathe
into the sensor for three seconds.
Position your thumb on the front
of the unit to help direct the 
sensor to your mouth. Do not
cover the sensor or back vent 
with your hand.

Note: Touch your thumb to your
chin so that the sensor is right
in front of your mouth. The
opening should be about 1/2"
(1 cm) away from your mouth.

4. For best results, breathe into the

sensor as if you are yawning. 
Try to breathe out the same
amount of air at the same speed
each time you test your breath.

5. When the test is complete, the

unit will beep. Your breath odor
level will appear on the display
and flash for several seconds.
Then the unit will turn off.

Note: The power will turn off auto-
matically if you don’t breathe into
the sensor within five seconds
after the display indicates you
should start measuring.

For the Most Accurate Readings

• Readings should not be taken during or immediately after

using mints or breathspray, eating or drinking. Wait at least 
ten minutes before using BreathAlert.

• Rinse your mouth thoroughly after cleaning your teeth or using

mouthwash. Wait at least ten minutes before using BreathAlert.

• BreathAlert is sensitive to certain environmental factors that

can interfere with the unit’s ability to detect breath odor level
correctly. For best results, avoid:

– Hot and humid places
– Windy areas
– Air polluted areas

Note: Usage in such environments may damage the product.

• If you don’t use BreathAlert for an extended period of time, test

your breath odor level several times to re-activate the product.

Federal Communications Commission Notice

This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that inter-
ference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver 

is connected.

• Consult the dealer or an experienced radio or television technician for help.

Modifications

The FCC requires the user to be notified that any changes or modifications made to this device
that are not expressly approved by Tanita Corporation may void the user’s authority to operate 
the equipment.

Turn the unit on

Breathe out

Batteries are low

Breath Odor Level

No 

odor

Error. 

Please try again

Slight 

odor

Moderate

 odor

Strong 

odor

Your breath odor level 

will appear

2

3

4

2

1

3 4

Wait for the numbers to 
disappear and the word

“Start” to show

B R E A T H   C H E C K E R

 

© 2000 Tanita Corporation. All rights reserved.
Patent pending.

Specifications 

BreathAlert (HC201E)

Display Results

4 Levels

Dimensions

3-1/2"H x 1-1/4"W x 5/8"D

Power Supply

DC 3V, LR03 Battery x 2 (included)

Should you need to return this 
product for an exchange or refund,
please contact the store/cataloger
from which it was purchased. 
Or call 1-800-TANITA-8 (USA and
Canada only).

Tanita UK Ltd.

The Barn, Philpots Close, Yiewsley, 
West Drayton, Middlesex, 
UB7 7RY, UK
Tel: 01895-438577
Fax: 01895-438511

Tanita Corporation of America Inc.

2625 South Clearbrook Drive
Arlington Heights, IL 60005, USA
Tel: 847-640-9241
Fax: 847-640-9261
www.tanita.com

This device features radio interference suppression
in compliance with EC Regulation 89/336EC.

Introduction

Thank you for purchasing BreathAlert. Read
these instructions before using your new
product and keep them for future reference. 

What Causes Breath Odor?

The vast majority of bad breath is caused by the presence of one or
more of the following: bacteria; decreased saliva; oral decay or 
disease; stress; food, alcohol or medication consumed; and the
lack of basic oral hygiene. In a few cases, bad breath can be caused
by respiratory infection, allergies or diseases such as diabetes and
emphysema. Most bad breath is temporary and will improve over
time. However chronic halitosis sufferers may require professional
treatment to manage their problem.

BreathAlert detects and measures the volatile sulfide compounds and
hydrocarbon gas that are present when breath is bad. Depending on
the amount measured, the unit displays the degree of odor in four
levels (see Breath Odor Level diagram).

Note: There are some odors that contain a type of gas that cannot
be detected by BreathAlert.

What to Do If BreathAlert Detects 
Breath Odor

80–90% of the time, breath odor can be easily corrected by
improving the condition inside of your mouth. 

• Brush and/or floss your teeth to remove any food remains.

• If the surface of your tongue is white, this indicates there are

food remains on your tongue. Brush your tongue 2–3 times
with a tooth brush.

• If you’re unable to brush your teeth, use a mouth spray or

chew gum.

• Drink plenty of water.

1

Sensor

2

LCD Display Screen

3

Power Button

4

Vent 

5

Battery Compartment

1

2

3

4

5

6

Odor Symbol

7

Battery Icon

2

1

3 4

LCD Display Screen

6

7

Summary of Contents for BREATH ALERT

Page 1: ...2 1 4 3 B R E A T H C H E C K E R ...

Page 2: ...n Thank you for purchasing BreathAlert Read these instructions before using your new product and keep them for future reference What Causes Breath Odor The vast majority of bad breath is caused by the presence of one or more of the following bacteria decreased saliva oral decay or disease stress food alcohol or medication consumed and the lack of basic oral hygiene In a few cases bad breath can be...

Page 3: ... gently in the air 4 5 times This will remove any odors or moisture left in the product 2 Turn the unit on by pushing the power button It will beep in response 3 The Odor Symbol will appear and count down from 3 1 When the word Start is displayed breathe into the sensor for three seconds Position your thumb on the front of the unit to help direct the sensor to your mouth Do not cover the sensor or...

Page 4: ...ctors that can interfere with the unit s ability to detect breath odor level correctly For best results avoid Hot and humid places Windy areas Air polluted areas Note Usage in such environments may damage the product If you don t use BreathAlert for an extended period of time test your breath odor level several times to re activate the product Fe Th pu ag rad ma fer to us Breath Odor Level No odor...

Page 5: ...s lower than expected Move away from wind or strong environmental odors or scents Make sure you wait until the display shows the word Start before taking a reading Hold the product about 1 2 1 cm away from your mouth Product Limite Not Valid Without Proof of Pu Your Tanita product is warranted to the o 1 year to be free from defects in materia use This product is designed for Perso of America rese...

Page 6: ...ress or implied warranties except as listed above Tanita is not liable for incidental or consequential damages for failure or malfunction of the product and any recovery may not be greater than the purchase price paid for this product Some states do not allow limitation on how long an implied warranty lasts or the exclu sion or limitation of incidental or consequential damages so the above lim ita...

Page 7: ... to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio or television technician for help Modifications The FCC requires the user...

Reviews: