9
1.1
Electrical Specification
1.1.1
The supply voltage for the equipment is 240/220/115V, single phase, 50/60Hz. Each
input will tolerate the following voltage variation:
240V +/- 10%
220V +/- 10%
115V +10% and -6%
1.1.2
The maximum power supply requirements will be 750VA.
1.1.3
The output voltages which are continuously obtainable from the equipment are as
follows:
a.
30kV DC positive with respect to earth
b.
30kV DC negative with respect to earth
c.
30kV DC positive and negative with respect to earth simultaneously, thus
giving 60kV DC between the outputs
1.1.4
The maximum output current obtainable from all outputs as detailed in 1.1.3. above
are as follows:
a.
5 milliamperes continuous
b.
10 milliamperes for a duty cycle of 5 minutes ON followed by 15 minutes OFF
load
1.1.5
The earthy end of the high voltage output is connected to the earth system of the
equipment.
Note:
There is a Voltage Dependent Resistor, internal connected between
neutral & chassis.