Chapter 20 – Technical Specifications
…table continued from previous page
Specification Type
Specification Details
Internal Pump Battery Life
4 years minimum under normal use conditions
Typical Operating Time when Pump
is Operating at Intermediate Rate
During normal use, the intermediate rate is 2 units/hr; battery charge can be reasonably expected to last up to
7 days from a fully charged state to a totally discharged state
Handling of Over-Infusion or
Under-Infusion
The method of delivery isolates the insulin chamber from the patient and the software performs frequent
monitoring of Pump status. Multiple software monitors provide redundant protection against unsafe conditions.
Over-infusion is mitigated by continuous self-tests, layering of redundancies and confirmations, and numerous
other safeguard alarms. Users are required to review and confirm the details of all bolus deliveries, basal rates,
and temp rates to ensure certainty before initiating a delivery. In addition, once bolus deliveries are confirmed,
the user is given 5 seconds to cancel the delivery before it is started. An optional Auto-Off alarm triggers when
the user has not interacted with the pump’s user interface for a pre-defined period of time.
Under-infusion is mitigated by occlusion detection and blood glucose monitoring as blood glucose entries are
recorded. Users are prompted to treat high blood glucose conditions with a correction bolus.
Bolus Volume at Release of Occlusion
(2 units per hour Basal)
Less than 3 units with Unomedical Comfort
™
(110cm) Infusion Set
Residual Insulin Remaining in the
Cartridge (unusable)
Less than 10 units
Minimum Audible Alarm Volume
45 dBA at 1 meter
Summary of Contents for t:slim X2
Page 2: ......
Page 14: ...Section 1 Before You Begin...
Page 15: ...Chapter 1 Introduction...
Page 19: ...Chapter 2 Important Safety Information...
Page 31: ...Chapter 3 Getting to Know Your t slim X2 Pump...
Page 54: ...Section 2 Key Pump Features...
Page 55: ...Chapter 4 Getting Started...
Page 61: ...Chapter 5 Infusion Site Care and Loading Cartridge...
Page 75: ...Chapter 6 Personal Profiles...
Page 85: ...Chapter 7 Bolus...
Page 93: ...Chapter 8 Stop Resume Insulin...
Page 96: ...Section 3 Additional Pump Operations...
Page 97: ...Chapter 9 Temporary Basal Rate...
Page 101: ...Chapter 10 Quick Bolus...
Page 105: ...Chapter 11 t slim X2 Pump Settings...
Page 109: ...Chapter 12 t slim X2 Pump Info and History...
Page 111: ...Chapter 13 t slim X2 Pump Reminders...
Page 117: ...Chapter 14 User Settable Alerts and Alarms...
Page 120: ...Section 4 t slim X2 Pump Safety Alerts and Alarms...
Page 121: ...Chapter 15 t slim X2 Pump Alerts...
Page 143: ...Chapter 16 t slim X2 Pump Alarms...
Page 157: ...Chapter 17 t slim X2 Pump Malfunction...
Page 160: ...Section 5 Living With and Caring for Your t slim X2 Pump...
Page 161: ...Chapter 18 Lifestyle Issues and Travel...
Page 165: ...Chapter 19 Taking Care of Your t slim X2 Pump...
Page 168: ...Section 6 Technical Specifications and Warranty...