Installing the Battery
Recording will start after the battery is inserted.
Explanation of Symbols
<Warning Symbols>

DANGER
These entries are actions that, if taken, may cause serious personal
physical damage or death.

CAUTION
These entries are actions that if taken may lead to physical injury or
damage to persons or things.
<Picture Symbols>
Denotes an important
warning or caution.
Denotes a
forbidden action.
Denotes an action
that should be
carried out.
DANGER
Do not take apart, repair or modify the Unit.
It may result in malfunction or unexpected accidents.
Do not use any batteries other than those specified in this Introductory
Manual.
Doing so may cause fire or malfunction.
If water or a foreign object enters into the Unit, immediately remove the battery
and stop using.
It may result in malfunction or unexpected accidents.
Store the Unit and accessories out of the reach of children. Touching them
may result in unexpected accidents.
Touching them may result in unexpected accidents.
If any smoke, strange smells or sounds are emitted from the Unit, immediately
remove the battery and stop using.
Continued use may cause fire or electrocution.
Please be careful not to touch the Unit during or after use in overly hot or cold
environments; it may cause burns or frostbite.
CAUTION
We are not responsible for any damage, malfunction or trouble, whether direct
or indirect, caused by the use of the Unit.Please be fully aware of this before
using our product.
This Unit has been designed for private and/or industrial use only.It is not for
use in situations where strict precautions are necessary such as in
connection with medical equipment, where directly or indirectly.
Battery life varies depending upon measuring environment, frequency of
communication, Unit settings, and battery performance.
The TR-52i becomes waterproof (splash proof) only after the temperature
sensor has been connected.
Without the sensor connected, neither the sensor jack of the Unit nor the connector part of the
temperature sensor is waterproof; make sure not to get wet.
Contact with oil may cause cracks to appear in the casing of the Unit.When
using the Unit in such an environment, protect the Unit by placing it inside a
polyethylene bag.
Do not use or store the Unit in such places as listed below; it may cause
electrocution, fire or damage to the Unit or to your computer.
-Areas exposed to direct sunlight
-Areas exposed in water or high-pressure water flow
-Areas exposed to organic solvents and corrosive gas
-Areas exposed to strong magnetic fields
-Areas exposed to static electricity.
-Areas near fire or exposed to excessive heat
-Areas exposed to excessive dust and smoke
Do not put fingers or foreign objects into the sensor jack.
Do not drop or expose the Unit to a strong impact.
It may cause damage.
Notices about this Introductory Manual
In order to properly use this product, please carefully read this manual before using.
T&D Corporation accepts no responsibility for any malfunction of and/or trouble with this product or with your computer that is caused by the improper handling of this product and will deem such trouble or
malfunction as falling outside the conditions for free repair outlined in the attached warranty.
- All rights of this Introductory Manual belong to T&D Corporation.It is prohibited to use, duplicate and/or arrange a part or whole of the manual without the permission of T&D Corporation.
- All registered trademarks, company names, product names and logos mentioned herein or for products being used are the property of T&D Corporation or of their respective owners. TANDD ,
"T&D", and the logo of T&D Corporation are all registered property of T&D Corporation.
- Specifications, design and other contents outlined in the manual are subject to change without notice due to continual improvements.
- Please follow the safety precautions outlined in the manual carefully. We cannot guarantee nor are we responsible for safety if this product is used in any manner other than was intended.
- On-screen messages in this manual may vary slightly from the actual messages.
- Please notify the distributor from which you purchased this product or T&D Corporation of any mistakes, errors or unclear explanations in this manual.T&D Corporation accepts no responsibility for any
damage or loss of income caused by the use of our product.
- This product has been designed for private or industrial use only.It is not for use in situations where strict safety precautions are necessary such as in connection with medical equipment, whether directly or indirectly.
- We are not responsible for any malfunction or trouble caused by the use of our product or for any problem caused by the use of measurement results of our product. Please be fully aware of this before using our product.
- This Introductory Manual cannot be reissued, so please keep it in a safe place.
- Please read the warranty and provisions for free repair carefully.
Safety Precautions and Instructions
The following items should be strictly obeyed for the safe usage of this product, and for protecting yourself and other people from bodily harm and/or damage to property.
To ensure the proper use of this product, we ask that before using it you carefully read, understand and follow the safety rules and precautions as outlined below.
1.
Remove the screws and open the cover.
Make sure to use the proper size and type of
screwdriver.(Phillips head #1 screwdriver)
2.
Insert the attached Battery.
Do not remove the battery from its tube casing.
3.
Check the rubber packing condition and close
the cover in the same manner as when you
opened it.
-If dirt or scratches are present on the rubber
packing, water resistance will be reduced.
Please remove the dirt or replace the rubber
packing if there're any cuts or scratches.
-Be sure to completely close the cover.
-Make sure not to over tighten the screws.
(
Appropriate torque: 20N/cm
〜
30N/cm
〔
2Kgf/cm
〜
3Kgf/cm
〕)
Notes about Battery Installation
- After inserting the battery, it may occur that nothing appears in the display
for about 10 seconds; this is not a malfunction.
- If a new battery has been installed and nothing appears in the display,
please remove and re-insert the battery.
- When inserting a battery, make sure no water or foreign objects get inside the case.
- Make sure that + and – are in the correct direction.
About Lithium Batteries
- Please store the lithium battery LS14250 in a place that is 20
℃
or less.
- When using lithium batteries other than LS14250 produced by SAFT, such as
CR2, product specifications cannot be guaranteed nor can the performance of
some functions, such as the battery warning function.
- Please avoid using the CR2 in the following situations:
Using the unit in an environment below 0
℃
or above 60
℃
Exposing the CR2 to continuous vibration such as in transportation
- When using a CR2 lithium battery, the tube is not necessary.
- To maintain waterproof capacity, when changing batteries also change the
rubber packing and the drying agent (silica gel). When using a CR2 lithium
battery, please purchase the optional Maintenance Set (TR-00P1) to replace
the rubber packing and silica gel.
Cover
Rubber Packing
Attached Battery
(with tube)
Screws
①
Thermistor
②
Fluoropolymer Coated Electrical Wire
③
Specialized Connector
Appearance Diagram and Part Names
Infrared Port
Optical
Communication Area
Sensor
Jack
ALM
(
Warning LED
)
Temperature Sensor TR-5106 (Supplied with TR-52i)
Thermo Recorder TR-51i/52i will be referred to as the
“
Unit
”
in this manual.
Make sure that the sensor is completely
inserted until you hear a
“
click
”
sound.
The TR-52i only becomes splash proof
when the sensor has been connected.
600
Waterproof
2.2
①
②
③
[unit: millimeters]
Specifications
Device Name
TR-51i
TR-52i
Measurement Item
Temperature
Temperature
Number of Channels
1 Ch (Internal Sensor Type)
1 Ch (External Sensor Type)
Measurement Range
- 40 to 80
℃
- 60 to 155
℃
Response Time (in 90% still air)
About 35 minutes
-
Measuring Accuracy
Avg.
±
0.5
℃
Avg. 0.3
℃
[-20 to 80
℃
]
Avg. 0.5
℃
[-40 to -20
℃
/ 80 to 110
℃
]
Avg. 1.0
℃
[-60 to -40
℃
/ 110 to 155
℃
]
Measurement Display Resolution
0.1
℃
Recording Intervals
Select from 15 choices:1, 2, 5, 10, 15, 20 and 30 seconds / 1, 2, 5,
10, 15, 20, 30 and 60 minutes
Storage Capacity
Up to 16,000 readings
Recording Start Method
Immediate Start / Programmed Start
Recording Modes
Endless / One Time
LCD Displayed Items
Measured Temperature, Recording Status, Recording Mode Infrared
Communication Status
Battery Life Warning, Unit of Measurement, Full (Storage Capacity
FULL), Unconnected Sensor
Measurement Range Exceeded, Upper/Lower Limit Exceeded
Communication Interfaces
Optical / Infrared Communication
Infrared Communication
IrPHY 1.2 low power
Communication Time
When downloading a Unit at full storage capacity:
Optical Communication : about 25 seconds (TR-50U) / about
150 seconds (other devices)
Infrared Communication: about 55 seconds (TR-57DCi)
Power
Lithium Battery (LS14250
)
Battery Life
(
*1
)
About 4 years ( 2 years if it
’
s been selected to
“
Permit
"
infrared
communication)
Waterproof Capacity
Immersion proof
Splash proof
(
*2
)
Dimensions
H62
×
W47
×
D19mm
(
excluding protrusions and sensor part
)
Weight
About 54g
(including battery)
About 55g (including battery / excluding sensor)
Operating Environment
- 40 to 80
℃
Data Collection Devices
Communication Ports
:
TR-50U2 / TR-50U
Data Collectors: TR-57DCi / 57U, RTR-57U
(*1) Battery life depends upon the measuring environment, recording interval, and quality of the battery being
used. When infrared communication function is enabled, battery life may be shortened if the unit is used under
the inverter type fluorescent lighting.
(*2) This is the waterproof capacity of the data logger with the sensor connected.
*The specifications listed above are subject to change without notice.
Temperature Sensor TR-5106
Sensor Temperature Durability
- 70 to 180
℃
Responsiveness
Thermal Time Constant:
Approx. 30 sec. (in air) / Approx. 4 sec. (in agitated water)
Response Time (90%):
Approx. 80 sec. (in air) / Approx. 7 sec. (in agitated water)
TR-51i
Internal Temperature Sensor Type
Immersion proof
TR-52i
External Temperature Sensor Type
Splash proof
Package Contents
:
Data Logger and Common Accessories for
TR-51i and TR-52i
Package Contents
:
Data Logger, Temperature Sensor TR-5106, and Common
Accessories for TR-51i and TR-52i.
Common Accessories for TR-51i and TR-52i
:
Lithium Battery LS14250 with Tube, Strap, Introductory Manual (including Warranty)
Introductory Manual
Thank you for purchasing this product.
Carefully read and fully understand these instructions before
using this unit.
Shimadachi 817-1, Matsumoto, Nagano 390-0852 Japan
Tel:+81-263-40-0131 Fax:+81-263-40-3152
Homepage:http://www.tandd.com/ E-mail:[email protected]
Copyright T&D Corporation. All rights reserved. 2016. 07 16504710011 (6th Edition)
This is printed using recycled paper.
Cautions about the Temperature Sensor
When using the included Sensor TR-5106, please take note of the following:
Do not bend or press the last 5 cm to the tip of the sensor, as this may
damage it.
This may cause trouble or break the wire.
If the fluoropolymer-coated section of the sensor and/or the cable has a
defect or tear, the waterproof capacity will be lost.
Inspect it before operation.
Insert the sensor tip to about 5cm or more to obtain on accurate temperature
measurement.
Only use the sensor within the sensor temperature durability range.
Radio, EMC and Safety Regulations
This device complies with Part 15 of the FCC Rules.
Operation is subject to following two conditions: (1) this device may not cause harmful
interference. and (2) this device must accept any interference received, including
interference that may cause undesired operation.
FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-- Consult the dealer or an experienced radio/TV technician for help.
T
o comply with the limits for the Class B digital device, pursuant to Part 15 of the FCC Rules, this device
must be installed in computer equipment certified to comply with the Class B limits.
All cables used to connect the computer and peripherals must be shielded and grounded. Operation
with non-certified computers or non-shielded cables may result in interference to radio or television
reception.
Caution
Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
Thermo Recorder TR-51i / 52i Warranty
Guarantee Period
1 year from date of purchase
Date of Purchase
Customer's name
Address
Phone No.
Distributor's name
Address
Phone No.
Object of Repair
Main Unit (excluding Input Modules and any other options.)
Method of Repair
Send in for Repair
Provisions for Free Repair
1. If the unit does not work properly despite the fact that the customer used it properly and in line
with the manual, the unit shall be repaired free of charge through the distributor which sold the
unit.
2. If the customer requests free repair because of trouble within the warranty period, bring or
send the unit along with the warranty to the distributor.
3. If you have moved after purchasing, or there are difficulties contacting the distributor from
which you purchased the unit, please contact T&D directly for service.
4. Free repair is not available in the following cases even though it is within the warranty period:
1. Trouble or damage was caused by careless operation, natural disaster, fire, public pollution,
or use of a power source other than specified.
2. If repair, adjustment, disassembly or modification of the unit has been carried out by a
person other than a T&D authorized engineer.
3. Trouble or damage was caused by transportation, movement or dropping of the unit after
purchase.
4. Failure to submit the warranty or failure to fill in all items required in the warranty.
5. The warranty cannot be reissued.
This warranty only promises customers free repair within the period and conditions clarified
in this warranty. Therefore, the customer's legal rights will not be limited by this warranty. For
further information on repair and other service questions after the termination of the warranty
period, contact your distributor.