T&D RTR-50 Manual Download Page 1

2006.12  16004474030

#OMMUNICATION0ORT

7IRELESS

242

© Copyright 2006 T&D Corporation. All rights reserved.

Summary of Contents for RTR-50

Page 1: ...2006 12 16004474030 OMMUNICATION 0ORT 7IRELESS 242 Copyright 2006 T D Corporation All rights reserved...

Page 2: ...ct to change without notice On screen messages in this manual may vary slightly from the actual messages Please notify the shop where you purchased this product or T D Corporation of any mistakes erro...

Page 3: ...whether direct or indirect from the inability to use RTR 50 for Windows T D Corporation has no obligation to correct any defects found in RTR 50 for Windows Copyright The Copyright for RTR 50 for Win...

Page 4: ...vice Driver Connection to the Computer 18 Windows XP 2000 18 Windows Me 98SE 19 If USB Device Driver Installation Fails 20 How to Re install 20 Connecting the RTR 50 with a serial communication cable...

Page 5: ...lation Range 83 Edit Recording Conditions 84 Re order Channel Data 85 Merge Channel Data 86 Erase Selected Channel Data 86 Vertical Axis Range Display Settings 87 Scale and Unit Conversion 89 Change G...

Page 6: ...of Symbols Explanation of Warning Symbols DANGER These entries are actions that absolutely under no circumstance should be taken The taking of such an action may cause serious personal physical damag...

Page 7: ...ain unit Doing so may cause fi re or electrocution Do not use this unit in wet or humid places such as a bathroom If any smoke or strage smells are emitted from the unit immediately remove the batteri...

Page 8: ...ause electrocution fi re and or other adverse effects to the device and or your computer Areas exposed to direct sunlight This will cause the inside of the device to become overheated and may cause fi...

Page 9: ...s been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interfere...

Page 10: ...1...

Page 11: ...2 1 Introduction...

Page 12: ...he RTR 5 Series Remote Data Logger unit you can use any RTR 50 as a Relay Unit for wireless communication 53 ABLE 3ERIAL ABLE RTR 50 PC Application Examples For the gathering of recorded data via wire...

Page 13: ...ion and make other Operational Settings Basic Functions Wireless Communication Start Recording Download Data Monitor Current Readings Warning Alarm Auto Download Get Remote Unit Status Wireless Commun...

Page 14: ...Monitoring at each location for warnings is carried out and if any of the gathered data exceeds the set limit a notification can be sent via e mail To properly use this software the following operati...

Page 15: ...Communication Port RTR 50 RTR 50 MS Windows 2000 Xp MS Windows 98SE Me FOR 242 242 262 Copyright 1995 2006 TandD Corporation All rights reserved 6ER 242 FOR 7INDOWS USB cable x 1 Software CD ROM OPYRI...

Page 16: ...7 Part Names and Functions Appearance Diagram ONITOR Front DAPTOR CONNECTION JACK 3ERIAL INI 53 INI Left Side Right Side Rear ATTERY OVER PTICAL OMMUNICATION 0ORT...

Page 17: ...8 2 Getting Ready This section provides instructions on getting the RTR 50 ready to use...

Page 18: ...9 General Procedure 1 RTR 50 for Win 3 RTR 50 AC 2 RTR 50 USB USB USB 4 RTR 50 for Win 5 6 RTR 50 for Win 7 P 10 P 11 P 10 P 28 P 28 P 46 P 67...

Page 19: ...teries NOTE When the RTR 50 is connected by USB cable to your computer there is no need to insert batteries Insert 2 AA alkaline batteries as shown in the figure NOTE Always use two batteries of the s...

Page 20: ...n the CR ROM drive In a few seconds the Install Program window will appear If that window does not automatically open please please open it by double clicking the CD ROM icon in My Computer on your de...

Page 21: ...vided USB communication cable US 15C to your computer It is not possible to simultaneously use both RTR 57U and RTR 50 USB Port Mark Make sure that the USB cable is inserted fully so as not to cause a...

Page 22: ...a USB port on the RTR 50 and your computer 53 ABLE 53 MINI 0LUG 53 MINI 0LUG To RTR 50 To PC RTR 50 2 Insert the attached CD ROM in the CR ROM drive If the Installation Window opens close it 3 By con...

Page 23: ...your computer the Found New Hardware Wizard will automatically open 4 By clicking the Next button a window will open where you can choose how you wish to find the driver file Next button 5 Check Searc...

Page 24: ...pens close it 3 By connecting an RTR 50 unit to the USB cable already connected to your computer the Add New Hardware Wizard will automatically open 4 By clicking the Next button a window will open wh...

Page 25: ...RTR 50 2 Insert the attached CD ROM in the CR ROM drive If the Installation Window opens close it 3 By connecting an RTR 50 unit to the USB cable already connected to your computer the Add New Hardwar...

Page 26: ...he Browse button Select Device Driver RTR 50 in the CD ROM drive and click Next Select Device Driver RTR 50 in the CD ROM drive Next button Browse button 7 After completing installation click the Fini...

Page 27: ...tem Properties will be displayed 2 Click the Hardware Tab and click the Device Manager button in the Device Manager Area Hardware tab Device Manager 3 In the Device Manager Window check to see if USB...

Page 28: ...tem the System Properties will be displayed 2 In the Device Manager Window check to see if USB Recorder 2 is listed under USB Recorder 2 COM Device Manager tab USB Recorder2 NOTE If the following tree...

Page 29: ...USB device driver must be re installed Please follow the directions below to carry out the operation How to Re install 1 In the Device Manager Window right click on USB Device under Other Devices and...

Page 30: ...is a D SUB 9 pin female jack that should be connected to the place with such a marking To RTR 50 To PC 3ERIAL ABLE NOTE Make sure to connect it to the correct place to ensure communication Make sure t...

Page 31: ...Auto Detect to automatically find an RTR 50 using the currently set communication method USB or Serial Auto Detect button Check 3 After the search if the message An RTR 50 unit was detected appears in...

Page 32: ...23...

Page 33: ...through how to use the software RTR 50 for Windows included with each RTR 50 unit The software is designed to allow for easy data processing creation of Graphs and management of all settings and regi...

Page 34: ...c Functions Open RTR 50 for Windows From the list of programs in the Window s Start Menu click on RTR 50 for Windows RTR 50 for Windows to open Explanation of Display RTR 50 for Windows Main Window Me...

Page 35: ...Data Start Recording Get Remote Unit Info Communication Port Settings Settings Menu Monitoring Monitoring Graph Settings View Warning Log Warning Report Mail Settings Mail Server Settings Auto Downlo...

Page 36: ...t is connected CH1 Upper Limit Displays the Upper Limit set in Monitoring Warning Monitoring for Warning Report CH1 Lower Limit Displays the Lower Limit set in Monitoring Warning Monitoring for Warnin...

Page 37: ...r computer see p 22 2 Register Remote Unit Name and Group Name Register all Remote Units to be placed ASE 5NIT 2EMOTE 5NIT ROUP For details about registering units as Remote Unit s see p 31 3 Register...

Page 38: ...sign a Relay Route Name that can be used to make sure that data is transmitted through a multiple number of Relay Units in the specified route NOTE It is possible to set up so that more than one Relay...

Page 39: ...LAY 5NIT 2ELAY 5NIT 2EMOTE 5NIT ROUP Communication will occur sequentially from the first Relay Unit as shown above If the Relay Units are not arranged in numerical sequence from the Base Unit the com...

Page 40: ...a new window 4 Place the Remote Unit data logger you wish to register face down on top of the RTR 50 After entering the Group Name and Remote Unit name click the New Registration Communication button...

Page 41: ...entially Communication Frequency Channel It is possible to set one Communication Frequency Channel channel 0 21 to each Group If no setting is made an unused frequency channel will automatically be as...

Page 42: ...Name will appear If you wish to register the currently displayed Remote Registration Contents without any changes click the New Registration Communication Button to add the received registration info...

Page 43: ...e Units registered to that Group If you wish to carry out communication with any such units they must be re registered or initialized Select the Group to be deleted Delete Group button Remote Unit Ini...

Page 44: ...s Communication Recording Mode The selected recording mode will be displayed Endless or One Time Endless Mode When the logger has reached its maximum number of readings 16 000 readings possible 8 000...

Page 45: ...ration Recording Settings from and click the Get Remote Unit Recording Settings Wireless Communication Tab Communication button Get Remote Unit Recording Settings Wireless Communication Tab 3 Click th...

Page 46: ...layed Remote Unit Name Remote Unit Name will be displayed Registration Status Displays whether the Remote Unit has been registered in the Remote Unit Registration List or not 1 Place the Remote Unit y...

Page 47: ...gistration Communication button Relay Route Name Memo Relay Unit Tab New Registration Communication button Memo It is helpful to make a memo entry here in order to distinguish between Relay Units Up t...

Page 48: ...were registered Not possible to change The registered Relay Unit and Remote Unit Group will appear in different background colors so as to be easily distinguishable Connect a Remote Unit via Relay Un...

Page 49: ...emote Unit from a Relay Route 1 Select the Remote Unit which you wish to remove from the Relay Route Then drag the Remote Unit to the Base Unit Icon and drop it 2 The location of the Remote Unit will...

Page 50: ...ion Select the Relay Unit to be deleted from the registration list Click the Delete Relay Unit if you wish to delete only the Relay Unit and click the Delete Route if you wish to delete the Relay Rout...

Page 51: ...lay Unit with a new one due to malfunction or trouble Select the Relay Unit you wish to replace from the Registration List and connect the one you wish to newly register to your computer with a USB or...

Page 52: ...43 RTR 50 0 5 1 PC 0 5 1 2 3 P 44...

Page 53: ...44 RTR 50 for Windows 0 5 0 5 1 USB 2 3...

Page 54: ...45 1 2 3...

Page 55: ...46 RTR 50 for Windows 3 Min 1 Max 5 1 1...

Page 56: ...47 1 1 1 2 1 RTR 50 for WIndows _ _ 1 1...

Page 57: ...48 RTR 50 for Windows Event OFF BAT USB USB USB...

Page 58: ...49 OK button OK 1 x 20 1...

Page 59: ...50 RTR 50 for Windows 1 1 2 P 53 Shift...

Page 60: ...51 1 1 1 x 20 1 2 5 10 15 20 30 1 2 5 10 15 20 30 60 16000 RTR 53 8000 FULL 16000 RTR 53 8000 1...

Page 61: ...52 RTR 50 for Windows 1 RVR 52 2 P53 3 Shift 1...

Page 62: ...53 1 1 x 20 1 2 5 10 15 20 30 1 2 5 10 15 20 30 60 16000 RTR 53 8000 FULL 16000 RTR 53 8000 1...

Page 63: ...54 RTR 50 for Windows OK RVR 52 V P Hi or Lo P...

Page 64: ...55 1 1 1 1 2 2 2 2...

Page 65: ...56 RTR 50 for Windows 20 1 Ch 1 Ch 2 OK P61...

Page 66: ...57 1 1 1000 1000 WarningLogList wlf...

Page 67: ...58 RTR 50 for Windows 1...

Page 68: ...59...

Page 69: ...60 RTR 50 for Windows 1 2 1 Ch1 2 Ch2 RTR 53...

Page 70: ...61 1 1 1 400 50 1 200 1 1...

Page 71: ...62 RTR 50 for Windows POP3 POP Before SMTP SMTP POP Before SMTP POP Before SMTP POP Before SMTP POP Before SMTP POP Before SMTP POP Before SMTP...

Page 72: ...63 1 2 1 3 4...

Page 73: ...64 RTR 50 for Windows RTR 50 for Windows 1000 1000...

Page 74: ...65 glf...

Page 75: ...66...

Page 76: ...67 4 Graph Operation...

Page 77: ...ttons at either side of the bar you can simultaneously move the A B cursors Click and drag the A or B button to move the cursor to the left or right A and B Cursor Position Information The approximate...

Page 78: ...Step by Step to Original Set High Low Avg Calculation Range Edit Recording Conditions Re order Channels Erase Selected Channels Data Vertical Axis Settings Print Help Hide View Channels Horizontal Ga...

Page 79: ...se operations can be carried out via commands in the Graph Menu or by clicking icons in the Toolbar About the Horizontal Axis The entire graph shows in the horizontal axis the nearest data to the reco...

Page 80: ...apsed Time Display Recorded Date Display Date Time Button This is a list of the data that was displayed in graph form The highest value is in RED lowest is in BLUE and the average is in PINK Scroll Ba...

Page 81: ...t the same operation Set High Low Average Calculation Range 1 Set the calculation range in the Set High Low Avg Calculation Range box 2 By clicking the OK button the high low average calculation range...

Page 82: ...will be displayed in the Edit Items 2 By clicking the OK button after changing the setting will be completed Restore button OK button The selected channel number Channel Number Enter letters and nume...

Page 83: ...Move by selecting the channel number 1 Enter in From the channel number you wish to move from and enter the channel number to which you want to move in To 2 By clicking the Re order button the movemen...

Page 84: ...ically change the temperature unit scale in the graph display and in the channel info list Change Graph Colors 1 Click the channel number of which you wish to change the color 2 By clicking each butto...

Page 85: ...utton you will return to the color settings when the software was opened Graph Line Width Settings Button Change the width of the data lines and the scale lines Every time you click on the numerical v...

Page 86: ...ut one step at a time Move Cursor Right Left Simultaneously move the AB Cursors to the right or left Move Graph Right Left Move the graph display to the right or left Move Graph Up Down Move the graph...

Page 87: ...l measured voltage A B Cursor Movement Buttons and A B Cursor Buttons By clicking one of the arrow buttons at either side of the bar you can simultaneously move the A B cursors Click and drag the A or...

Page 88: ...n choose from an array of commands Toolbar Buttons appear for frequently used commands Open File Overwrite Data Data List Display Return to Original Size Step by Step to Original Set High Low Avg Calc...

Page 89: ...g the mouse to outline the area you want to zoom in on Menu Display Using the Mouse By right clicking on the graph the Menu will be displayed With Return to Original Size or Step by Step Return to Ori...

Page 90: ...tarted Elapsed Time Display Recorded Date Display Date Time Button This is a list of the data that was displayed in graph form The highest value is in RED lowest is in BLUE and the average is in PINK...

Page 91: ...splay Check By clicking a Channel Number in the Toolbar you can carry out the same operation Scale Display ON OFF 1 The channel numbers are displayed in the pull down menu of Selected Scale ON OFF 2 P...

Page 92: ...utton Entire Graph button Enter the numerical value Entire Graph Button To make the Calculation Range that of the Entire Graph click the Entire Graph button The dates and times in the Set High Low Avg...

Page 93: ...nel Number Restore button OK button Enter letters and numerical values The selected channel number Name Up to 32 letters can be entered Starting Date Time The month day year hour minute and second can...

Page 94: ...ove and drag and drop it to the desired new channel position Move by selecting the channel number 1 Enter in From the Channel number you wish to move from and enter the Channel number to which you wan...

Page 95: ...e different Merging is possible between same types of data like temperature humidity OK button Merge button Ex If you wish to merge Ch 3 with Ch 7 2 By clicking the Merge button the merging will be co...

Page 96: ...mit at less than 40 000 3 By clicking the OK button the setting will be completed Select Fixed and enter numerical values Check here If you wish to make all of the settings the same OK button Make all...

Page 97: ...88 Graph...

Page 98: ...nate by y ax b tab OK button Designate by 2 points tab Conversion Info Designate by y ax b tab 2 Set conversion formulas and units 3 By clicking the OK button the setting will be completed Conversion...

Page 99: ...me you click the button the width gets wider and every time you click the button the width becomes more narrow 2 Confirm the width in the image preview and click the Close button to complete the chang...

Page 100: ...function from which you can choose from an array of commands Toolbar Buttons appear for frequently used commands Open File Save Data as Save as Text File Shift Display Display in ascending order Disp...

Page 101: ...corded date and the amount of elapsed time from the last recorded data Recorded Date Display Elapsed Time Display Shift Ascending Descending You can shift the display to view the recorded data either...

Page 102: ...t File Info from the View Menu 2 Click the OK button to return to the previous window File Name File name of data currently in display Path Location where file is saved Date Created The date and time...

Page 103: ...t Preview will appear After confirming it is what you wish to print click Print to start printing Button Functions Print Print box will appear and printing will begin Previous Preview the previous pag...

Page 104: ...to file without changing File Name and Saving Location The same operation can be carried out from Save in the Toolbar In the File Menu select Save All Data as Save with a new File Name In the File Me...

Page 105: ...File Menu select Save All Data as Save with a new File Name Specify Location Enter a File Name Save button 1 Select Save All Data as in the File Menu 2 Specify the Location and enter a File Name 3 Cl...

Page 106: ...and Semi colon are codes used by common spreadsheet software such as Excel and Lotus when reading Text File to divide cells 3 Designate the location to which the file should be saved and click Save to...

Page 107: ...by common spreadsheet software such as Excel and Lotus when reading Text File to divide cells OK button Designate File button Select the Text File Type 3 Designate the location to which the file shoul...

Page 108: ...elect the files you with to open NOTE See p 62 for details about compatible data file types Opening a File with the Temp Humid Graph and Multi scale Graph 1 Select Open in the File Menu 2 Select the n...

Page 109: ...File with the Event Viewer 1 Open the Event Viewer from the RTR 57C 57U or RVR 52A Graph Menu 2 In the Event Viewer Window under the File Menu click Open and a list will apper Open button Select a Fil...

Page 110: ...101...

Page 111: ...102 Others Others...

Page 112: ...th the other computer If you have a computer with energy saving function settings make sure that the serial port has not been turned off Especially on NEC brand PC98 notebook computers the default set...

Page 113: ...an unusable communication port Select the port with a mark and then click on Properties to view the details about that port If your computer has an internal modem make sure that the communication por...

Page 114: ...dapter gender changer plug as explained below If the connector on your computer is a D SUB 9 pin male then there is no need for an adapter If the connector on your computer is a D SUB 25 pin female th...

Page 115: ...R 51 RTR 52 RTR 53 RVR 52 RTR 5 RVR 5 Lo Hi Hi Lo RTR 50 Temp Humidity Graph Graph Temp Humidity Graphs for Each Channnel Zoom out in and scroll Change Channel Colors Turn ON and OFF Channnel Display...

Page 116: ...isplay 2 AB 2 AB ss 8 RTR 53 4 RTR 51 52 RVR 52 8 Others Event Viewer Event List Lo Hi Hi Lo 64 RVR 52 OS Microsoft Windows 98SE Me Microsoft Windows 2000 XP PC CPU Pentium 90MHz AT NEC 98 USB RS 232C...

Page 117: ...50 RTR 5 RVR 5 USB 2 AC AD 0601 EIAJ 2 USB MiniB 19200bps ARIB STD T67 426MHz 4 100m FULL 420 FULL 160 LED PC x 2 1 5 6 95 mm 65 mm 24 5 mm 60g 2 5V 7 0V 50mA 10 60 30 60 20 80 RH USB CD TR 07C AC AD...

Page 118: ...109...

Page 119: ...ga Matsumoto Nagano Japan 399 0033 Tel 81 263 27 2131 Fax 81 263 26 4281 E mail overseas tandd co jp Office Hours Monday to Friday 9 00 12 00 13 00 17 00 GMT 9 00 Tokyo Time RTR 50 Wireless Communicat...

Page 120: ...to submit a defective product for repair or replacement during the warranty period should first contact the dealer from whom it was originally purchased After receiving a return authorization the defe...

Reviews: