Installing the Equipment
Page 2-8
Reference Guide: Voyager E5784 and E5788 HD DSNG Encoder
ST.RE.E10137.3
Table 2.2: Non Standard Supply Cord Wire Colours
Wire Colour (UK)
Action
green-and-yellow
...must be connected to the terminal in the plug which is marked with the letter E or the safety earth
symbol or coloured green or green-and-yellow.
blue
...must be connected to the terminal in the plug which is marked with the letter N or coloured black.
brown
...must be connected to the terminal in the plug which is marked with the letter L or coloured red.
Protective Earth/Technical Earth
WARNINGS...
1.
THIS UNIT MUST BE CORRECTLY EARTHED THROUGH THE MOULDED PLUG SUPPLIED.
IF THE LOCAL MAINS SUPPLY DOES NOT HAVE AN EARTH CONDUCTOR DO NOT
CONNECT THE UNIT. CONTACT CUSTOMER SERVICES FOR ADVICE.
2.
BEFORE CONNECTING THE UNIT TO THE SUPPLY, CHECK THE SUPPLY REQUIREMENTS
IN ANNEX B.
The unit has a Technical earth terminal (marked with ) located at the
rear panel. Its use is recommended. This is NOT a Protective earth for
electric shock protection. The terminal is provided to:
1. Ensure all equipment chassis fixed within a rack are at the same
Technical earth potential. To do this, connect a wire between the
Technical earth terminal and a suitable point on the rack.
2. Eliminate the migration of stray charges when connecting between
equipment.
WARNING...
IF THE TERMINAL SCREW HAS TO BE REPLACED, USE A M5 X 12mm LONG POZIDRIV
PANHEAD. USING A LONGER SCREW MAY CAUSE A SAFETY HAZARD.
Connecting the Encoder to the AC Power Supply
WARNINGS...
1. DO NOT OVERLOAD WALL OUTLETS AND EXTENSION CORDS AS THIS CAN RESULT IN A
RISK OF FIRE OR ELECTRIC SHOCK.
2. AS NO MAINS SWITCH IS FITTED TO THIS UNIT, ENSURE THE LOCAL AC POWER SUPPLY
IS SWITCHED OFF BEFORE CONNECTING THE SUPPLY CORD.
3. THE ENCODER IS NOT FITTED WITH AN ON/OFF SWITCH. ENSURE THAT THE
SOCKET-OUTLET IS INSTALLED NEAR THE EQUIPMENT SO THAT IT IS EASILY
ACCESSIBLE. FAILURE TO ISOLATE THE EQUIPMENT PROPERLY MAY CAUSE A SAFETY
HAZARD.
To connect the unit to the local a.c. power supply:
1.
Ensure the local a.c. supply is switched OFF.
2.
Ensure the correct fuse type and rating has been fitted to both the
equipment and the a.c. power cable.
3.
Connect the a.c. power lead to the Encoder mains input connector and
then to the local mains supply.