Operating the Equipment Locally — Setup Menu: Video Menu
Page 4-20
Reference Guide: Voyager E5784 and E5788 HD DSNG Encoder
ST.RE.E10137.3
SI Level Option
This enables the service information level to be specified.
Table 4.4: SI Level Options
Selected Option
Description
PAT/PMT/CAT only
Program Association Table/ Program Map Table/ Conditional
Access Table.
PAT/PMT only
Program Association Table/ Program Map Table.
Off
Elementary streams only.
On (PSIP)
PAT/PMT/CAT/TDT/SDT/NIT/EIT – minimum DVB.
On (Ext. PSIP)
PAT/PMT/CAT/TDT/SDT/NIT.
Ext. PSIP Source Option
This option only applies if the SI level has been set to On (Ext. PSIP). It
specifies the Remux input through which the external PSIP is to be
received.
PSIP Status
This option only applies if the SI level has been set to On (Ext. PSIP). It
reports the range of PIDs that will be passed through the external PSIP
input.
PSIP Min PID
This option only applies if the SI level has been set to On (Ext. PSIP). This
sets the minimum PID value that will be passed through the external PSIP
input.
PSIP Max PID
This option only applies if the SI level has been set to On (Ext. PSIP). This
sets the maximum PID value that will be passed through the external PSIP
input.
Data n min/max
This option enables a PIDmin and PIDmax range to be selected for a
specified input [n]. All PIDs lying within this range are passed through. No
attempt to extract SI information nor interpret SI/PSI information is made
on this input.
The Encoder is not able to build accurate PSI tables when in data remux
mode as it does not extract any info from the incoming stream. Therefore,
in this case, it is necessary for PSI/PSIP to be externally generated.
There must be no PID clashes (between other inputs or the locally
generated streams) as PID clashes are not resolved nor detected by the
Encoder.
Major Channel Option
This is associated with the field major_channel_number and is used to
group all channels that are to be identified as belonging to a particular
broadcast corporation.