OPERATORS MANUAL
TT1200 MPEG2-DVB PROFESSIONAL DECODER
PAGE 38
TANDBERG TELEVISION ASA, Philip Pedersensvei 20, PO Box 322, N-1324 Lysaker, Norway
Tel: +47 67 11 62 00, Fax: +47 67 11 62 01
Audio PTS:
Not used
Lip sync:
Very poor, limited by the size of the audio and video bit
buffers and the bit rates of the video and audio streams.
5.4.5.3 Alarm Setup menu
Whenever an alarm condition occours, the alarm relay is activated (see section 3.6 Alarm connectors),
and the
System Status
display will display
Status: ALARM
. The possible alarm conditions are
given by a number of Status messages. Each of the status messages can be configured to activate one of
three alarm levels:
$
ALARM
:
WARNING
DISABLED
The ‘
-
’ means that the error message is considered unimportant and should be ignored if it occurs. ‘
W
’
means that a warning messages is generated on the status display if the error message occurs. ‘
A
’ means
that this error message is considered to be a serious fault, an alarm message is generated and the alarm
relay on the TT1200 will be switched to ALARM.
Entering the
Alarm Setup
menu, the different status messages can be edited by first selecting type of
message. The status messages are organised according to which part of the decoder they originate. The
available status messages are shown in Appendix 1. The
Alarm setup
menu is shown in Figure 22.