Alarm Categories and Conditions
Page D-6
Reference Guide: TT1222 4:2:0 Professional Receiver
ST.RE.TT1222.2
D.3.4 Data
Output
Alarms
The data output alarms reflect the status of the LS data (RS-232) output
port and its associated functions.
Table D.6: Data Output Alarm Categories and Conditions
Alarm Category
Contents
Alarm Description
Remedy
Default
Error in
stream
Cannot decode the
component stream.
Make sure the
correct component
is selected
A
CC failure
TS has missing packets on
the incoming transport
stream.
Improve input
signals, or check
source
W
Buffer
overflow
Output port rate is lower than
incoming data rate.
Increase output rate
or select new
component
A
Not used
No PID selected to decode.
Select PID or turn of
data output
A
Data output:
Same PID
The selected PID is in use by
another part of the Decoder.
Choose a different
PID.
W
D.4
CA and PSI/SI Related Errors
D.4.1
CA Related Alarms
The CA status alarms indicate the current condition of the CA system
Table D.7: CA Related Alarm Categories and Conditions
Alarm Category
Contents
Alarm Description
Remedy
Default
CA system:
No access
The DVB common interface
module has no access to the
currently selected
component.
Check conditional
access entitlements
with service
provider.
W
Summary of Contents for TT-1222
Page 10: ...Introduction Page 1 2 Reference Guide TT1222 4 2 0 Professional Receiver ST RE TT1222 2 BLANK...
Page 32: ...Options Page 3 2 Reference Guide TT1222 4 2 0 Professional receiver ST RE TT1222 2 BLANK...
Page 38: ...Options Page 3 8 Reference Guide TT1222 4 2 0 Professional receiver ST RE TT1222 2 BLANK...
Page 50: ...Alarms GPOs Page 6 2 Reference Guide TT1222 4 2 0 Professional Receiver ST RE TT1222 2 BLANK...
Page 56: ...Alarms GPOs Page 6 8 Reference Guide TT1222 4 2 0 Professional Receiver ST RE TT1222 2 BLANK...