User Guide
External Charger
FieldView
D14059.02
April 2007
Page 1: ...User Guide External Charger FieldView D14059 02 April 2007...
Page 2: ...arger from A C Do not touch the external charger until you have unplugged it from the AC outlet Do not place anything over the external charger during use Never drop anything on the external charger D...
Page 3: ...tart 1 Setup 1 Charger Operation 1 Inserting the Battery 1 Basic Operation 2 Error Conditions 2 Smart Battery State versus Actual State 2 Battery Conditioning Cycle 2 Starting a Battery Conditioning C...
Page 4: ...a battery is not installed in the charger Place the charger on a flat dry stable surface Plug the barrel jack from the power supply into the back of the charger Plug the AC DC power adapter into your...
Page 5: ...energy of the smart battery can become out of sync with the actual available energy When a battery is first inserted into the external charger the charger will check the reported available energy agai...
Page 6: ...ery P N 116314 Li Ion Battery into charger When the battery starts to charge the Status LED will be red and the Mode LED will be green Wait until the battery has been fully charged before removing fro...
Page 7: ...ge current tolerance 20 Precharge threshold 6 0V typ Precharge current 300mA Efficiency 85 min Charge time 4 hrs max Charge timeout limit 6 0 hrs Charge operation temperature 0 50 C Humidity 0 85 non...
Page 8: ...E mail tandberg tandberg com Support North America only 1 866 826 3237...