d. Drive Configuration

The text “Current Drive Configuration” will disappear as soon you change any of the pa-
rameters. It will reappear, if you change them back to their original values or click the 

Save

button.

In other words: This text tells you that the parameter values displayed are the same as the val-
ues saved in the drive.

If you have changed some of the values, but want to return to the drives saved values, click
the 

Refresh

 button.

Note: The EOWR parameter makes the drive simulate old ½” tape drives. This is normally
only used in some Unix systems. Please refer to the SCSI programming manual for further
information.

The button marked 

FW update

 facilitates drive upgrade. When pushed, the user will be

prompted to locate the file with the applicable binary code, after which the flashing process
will commence. When completed, the drive information on the screen will be automatically
updated. In case that the flashing fails (e.g. a corrupt or not applicable binary file was sup-
plied) the user will be notified, but the drive will not be affected.

Summary of Contents for TDKIT

Page 1: ...TDkit USER s GUIDE CONFIGURATION AND TEST TOOL FOR TANDBERG TAPE DRIVES Part No 43 33 28 01 August 2005 TANDBERG DATA ASA P O Box 134 Kjels s N 0411 OSLO NORWAY Phone 47 22 18 90 90 Telefax 47 22 18...

Page 2: ...1 Introduction 3 2 Known bugs and limitations 3 3 System requirements 3 4 Supported tape devices 4 5 Using TDkit 4 a The tab selected pages 6 b SCSI Overview 6 c Additional Drive Info 7 d Drive Confi...

Page 3: ...is running Error logging to file is not implemented in this revision 3 System requirements TDkit runs in Windows 32 bit environments such as Windows 98 Windows ME WinNT Win2000 Win2003 and XP It can b...

Page 4: ...50 SLR60 SLR75 SLR100 SLR140 420LTO TS400 5 Using TDkit During startup the TDkit detects and displays connected adapters and devices The first tape drive detected if any will be activated and availabl...

Page 5: ...on can be suppressed by using the run time option IDLE In either case the user may freely trigger suspend polling using this menu option Note that when polling is disabled the Medium Info button appea...

Page 6: ...will display the different pages depending on the actions the user wants see below b SCSI Overview Only the radio buttons representing a connected active device are enabled Select device by clicking...

Page 7: ...c Additional Drive Info The meaning of the Cleaning flag status is also displayed in text Cleaning not needed in green or Cleaning needed in red Note that some older products like SLR2 5 do not sup p...

Page 8: ...the file where the dump will be saved Note that the dump is formatted in ASCII but due to its specific contents it is basically in tended only for the TD personell Note also that the button may be mi...

Page 9: ...ves saved values click the Refresh button Note The EOWR parameter makes the drive simulate old tape drives This is normally only used in some Unix systems Please refer to the SCSI programming manual f...

Page 10: ...est fails a corresponding SCSI error message will be dis played HW compression is disabled during the test Note that this test expects a cartridge to be in the drive and the data on the tape if any wi...

Page 11: ...ack to the beginning of tape if ap plicable for the given device Unload will unlock the drive if prevented by host and eject the tape Note that SLR2 5 will be unlocked and logically unloaded tape not...

Reviews: