1.4. Safety instructions

Note:

The  track   occupancy   indicator   contains   integrated   circuits   (ICs).   These   are   sensitive   to
electrostatic   charging.   Therefore,   do   not   touch   these   components   until   you   have
"discharged" yourself. For this purpose, e.g. a grip on a radiator is sufficient.

Improper use and non-observance of the instructions can lead to incalculable hazards. Prevent
these dangers by carrying out the following measures:

Only use the track occupancy indicator in closed, clean and dry rooms. Avoid moisture and
splash   water   in   the   environment.   After   condensation   has   formed,   wait   two   hours   for
acclimatisation before use. 

Disconnect the track occupancy indicator from the power supply before carrying out wiring
work. 

Supply   the  track   occupancy   indicator   only   with   extra-low   voltage   as   specified   in   the
technical data. Use only tested and approved transformers.

Only plug the mains plugs of transformers into properly installed and fused earthed sockets.

When making electrical connections, ensure that the cable cross-section is sufficient.

Heating of the track occupancy indicator during operation is normal and harmless. 

Do   not   expose   the  track   occupancy   indicator   to   high   ambient   temperatures   or   direct
sunlight. Observe the information on the maximum operating temperature in the technical
data.

Regularly check the operational safety of the track occupancy indicator, e.g. for damage to
the connection cables. 

If you notice damage or if malfunctions occur, disconnect the connection to the power
supply immediately. Send the track occupancy indicator in for inspection.  

1.5. Care

Do not use any cleaning agents to clean the  track occupancy indicator. Only wipe the track
occupancy indicator dry. Disconnect the indicator from the power supply before cleaning. 

Getting started | 5

Summary of Contents for GBM-8.2

Page 1: ...GBM 8 2 Track Occupancy Indicator 8 fold Manual Item no 52 01186 52 01187 tams elektronik n n n...

Page 2: ...technical changes Printing the manual The formatting is optimised for double sided printing The standard page size is DIN A5 If you prefer a larger display printing on DIN A4 is recommended The asteri...

Page 3: ...Connections GBM 8 2 8 3 1 Connecting the power supply and the track sections 8 3 3 Connection of LEDs 10 3 4 Connection of digital feedback modules 11 4 Setting the sensitivity 12 5 Checklist for tro...

Page 4: ...Stranded wires consist of several thin individual wires and are therefore more flexible than rigid wires with the same copper cross section Recommended cross sections Connections to the tracks and the...

Page 5: ...oltage as specified in the technical data Use only tested and approved transformers Only plug the mains plugs of transformers into properly installed and fused earthed sockets When making electrical c...

Page 6: ...cted directly to the outputs Display of the busy messages To display the busy messages LEDs with suitable series resistors can be connected to the outputs of the GBM 8 2 Since the outputs of the GBM 8...

Page 7: ...nputs and outputs of the GBM 8 2 are galvanically separated from each other by optocouplers This filters out interference peaks and effectively prevents ground loops hum loops and fault currents Info...

Page 8: ...to 3 rail systems Connecting the power supply Please note that all track sections must be in one booster circuit or must be supplied via a common driving transformer GBM 8 2 Track output of the booste...

Page 9: ...re detected that enter the track section in the direction marked as direction of travel in the connection diagram GBM 8 2 Connection to G1 G2 G3 G8 isolated conductors in the track sections V1 uninter...

Page 10: ...If you use the driving transformer to supply the LEDs the equalising currents that occur can damage connected components Supply with alternating voltage If you connect the LEDs to an AC transformer yo...

Page 11: ...les You can connect the inputs of digital feedback modules that switch to ground e g s88 feedback modules directly to the outputs of the GBM 8 2 Connect the ground output of the feedback module to one...

Page 12: ...ensitivity of the track occupancy detector for each of the 8 track sections at the associated trim pot Use a small screwdriver for the adjustment Settings Left stop highest sensitivity setting on deli...

Page 13: ...ut the use of your track occupancy indicator our technical hotline will help you telephone number and e mail address on the last page 5 2 Repairs You can send us a defective track occupancy indicator...

Page 14: ...ly via the rails Note All track sections must be in one booster circuit or supplied via a common driving transformer Current consumption without connected loads approx 15 mA Max current in the track s...

Page 15: ...ion 10 85 non condensing Ambient temperature during storage 10 40 C Permissible relative humidity during storage 10 85 non condensing Other features Dimensions approx Circuit board 63 x 97 mm Ready de...

Page 16: ...of the components as well as the function of the parts according to the parameters in not mounted state We guarantee the adherence to the technical specifications when the kit has been assembled and t...

Page 17: ...s product is subject to the requirements of the EU Directive 2012 19 EC on Waste Electrical and Electronic Equipment WEEE i e the manufacturer distributor or seller of the product must contribute to t...

Page 18: ...GBM 8 2 tams elektronik 18...

Page 19: ...tams elektronik GBM 8 2 19...

Page 20: ...ation and Tips n n http www tams online de n n n n Warranty and Service n n Tams Elektronik GmbH n Fuhrberger Stra e 4 DE 30625 Hannover n fon 49 0 511 55 60 60 fax 49 0 511 55 61 61 n e mail modellba...

Reviews: