Locomotive decoders of the series 30 plus
English
9. Performing a POM-Update
Hint: The POM-Update is possible with decoders from version 2.4
(LD-G-31 plus) or version 2.5 (LD-G-33 plus and LD-G-34 plus). For
updating decoders with a former firmware version you have to send
them in. The version number is saved in CV #7.
Preparations
1. In order to perform the firmware update you do
not
have to
dismount the decoder. Put the vehicle with the mounted decoder
on the main track. Hint: You can perform a firmware update with
several locomotive decoders of the same type at once, the current
software version of the decoders is of no importance. The individual
CV settings of the decoder will not be altered by updating.
2. Save the file with the newest firmware on your PC,
e.g. LD-G-31_plus_V2_5_0_0.hex for version 2.5.0.0
You can download the newest firmware from our homepage
without charge. When getting (on the part of any third parties) a
packed file (e.g. *.zip) you have to unpack it first.
3. Get ready the CD with the program "POM-Updater.exe" (included in
the delivery) or download the program from our homepage.
4. Connect your central unit with the PC. At present (status: 01/2015)
the POM-Update can be carried out with the MasterControl (Tams
Elektronik), the Intellibox 1 (Uhlenbrock**) and the CS2
(Maerklin**) ). You find the current list of central units allowing to
perform the POM-update on our homepage.
5. Before starting the update connect at least one lamp or LED to F0f
as the update´s status is shown by lighting or flashing of the
lighting connected to this output.
Page 81