background image

4516 112 Ave S.E. Calgary,

 Alberta • 

Te

l: (403) 279 0020 • 

Fax: (403) 279 0747

www.tamashydronic.com

Tamas Hydronic Panels

User Guide

Low Loss Header Series

Installation and Commissioning Guide

Version 1.0

Summary of Contents for Low Loss Header Series

Page 1: ...4516 112 Ave S E Calgary Alberta Tel 403 279 0020 Fax 403 279 0747 www tamashydronic com Tamas Hydronic Panels User Guide Low Loss Header Series Installation and Commissioning Guide Version 1 0 ...

Page 2: ...0 Low Loss Header Panel with UPS 15 58 Pumps 1 Boiler Pump and 2 High Temp Zone T LL BO 1300 Low Loss Header Panel with UPS 15 58 Pumps 1 Boiler Pump and 3 High Temp Zone T LL BO 1110 Low Loss Header Panel with UPS 15 58 Pumps 1 Boiler Pump 1 High Temp Zone and 1 Low Temp Zone 1 TMV T LL BO 2010 Low Loss Header Panel with 1 26 99 Boiler Pump and 1 Low Temp Zone T LL BO 2020 Low Loss Header Panel w...

Page 3: ...ss Header with an Expansion Module and 4 Low Temp Zones T LL EX 0110 Low Loss Header with an Expansion Module 1 High Temp Zone and 1 Low Temp Zone T LL EX 0120 Low Loss Header with an Expansion Module 1 High Temp Zone and 2 Low Temp Zones T LL EX 0130 Low Loss Header with an Expansion Module 1 High Temp Zone and 3 Low Temp Zones T LL EX 0210 Low Loss Header with an Expansion Module 2 High Temp Zon...

Page 4: ...s as well as low and high temperature zones can be added to the system This enables the panel to accommodate DHW priority or fan coil applications The panel can support a maximum of 5 pumps including the DHW priority pump Installation Prior to mounting the panel ensure the wall is capable of supporting the weight of the panel Ensure that an 115V receptacle is within reach of the 5 foot cord and pl...

Page 5: ...2 x 26 Galvanized Backpan 2 Tamas Control Box with 5 Power Cable 3 Zone Pumps UPS 15 58 4 24V AC Transformer with Internal Fuse 5 Temperature Gauge 6 Tamas Ball Valves 7 Stainless Steel Low Loss Header 8 Hose Bib Hook Up 9 Manual Air Vent Components 1 1 2 2 2 2 3 3 3 3 6 6 7 7 6 6 7 7 8 8 9 9 4 4 5 5 5 5 21 5 27 21 5 27 Low Loss Header Panel Components 12 ...

Page 6: ...ponents 1 22 x 26 Galvanized Backpan 2 Tamas Control Box with 5 Power Cable 3 Zone Pumps UPS 15 58 4 24V AC Transformer with Internal Fuse 5 Temperature Gauge 6 Tamas Ball Valves 7 Thermostatic Mixing Valve Components 1 1 1 1 2 2 2 2 3 3 3 3 6 6 7 7 6 6 7 7 8 8 9 9 10 10 4 4 5 5 5 5 21 5 27 21 5 27 Low Loss Header Expansion Panel Components 12 ...

Page 7: ...vanized Backpan 2 Tamas Control Box with 5 Power Cable 3 Zone Pumps UPS 15 58 4 24V AC Transformer with Internal Fuse 5 Temperature Gauge 6 Tamas Ball Valves 7 Stainless Steel Low Loss Header 8 Hose Bib Hook Up 9 Air Vent 10 Boiler Pump UPS15 58 UPS 26 99 Components 1 1 1 1 2 2 3 3 6 6 7 7 8 8 9 9 10 10 4 4 4 4 5 5 21 5 27 Low Loss Header Boiler Panel Components 12 ...

Page 8: ...s When the room temperature is satisfied the thermostat or aquastat disconnects the heat source and pump 3 Temp Low Loss Header Panel Application 3 Temp Low Loss Header Panel with Expansion Panel Application Operation Operation of the Domestic Hot Water DHW When there is a Domestic Hot Water application and an aquastat demand is signaled the panel disconnects the active zone pumps and sends a mess...

Page 9: ...e UPS 15 58 3 Speed Pump 230o F s l a v o r p p A m e t s y s d e s o l c p m e t d i u l f x a M 150o F L T E m e t s y s n e p o p m e t d i u l f x a M 36o F Min fluid temp NSF Std 61 10 Bar Max system pressure Annex G HI MED LOW HI MED LOW 20 18 16 14 12 10 8 6 4 2 0 80 70 60 50 40 30 20 0 0 2 4 6 8 10 12 2 4 6 GPM Ft GPM Watts 8 10 12 UPS 15 58 Three Speed Pump ...

Page 10: ...ature 36 F 2 C Maximum working pressure 145 PSI 0 5 10 15 20 25 30 0 5 10 15 20 25 30 35 Flow GPM Head ft HI MED LOW Without Check Valve With Check Valve MODEL VOLTS AMPS WATTS HP CAPACITOR Spd 3 1 8 197 1 6 20mF 180V Spd 2 1 5 179 1 6 20mF 180V Spd 1 1 3 150 1 6 20mF 180V Spd 3 0 9 196 1 6 5mF 400V Spd 2 0 8 179 1 6 5mF 400V Spd 1 0 7 150 1 6 5mF 400V 115V 230V Model Type A B C D E F Connection T...

Page 11: ... working pressure 150 psi 10 bar Maximum system differential pressure between hot and cold 44 psi 3 bar Maximum system differential pressure 72 psi 5 bar Maximum hot water inlet temperature 194 F 90 C Minimum required flow 0 5 US gpm The thermostatic mixing valve will provide a mixed water temperature according to the table below The outlet temperatures stated are approximate based on given hot wa...

Page 12: ... com Page 12 Tamas Hydronic Panels Low Loss Header Series Technical Data Tamas Low Loss Header Delta T Max Flow Rate BTU Load 20 24 2GPM 242000 25 24 2GPM 280000 30 24 2GPM 365000 35 24 2GPM 420000 40 24 2GPM 475000 Dimensions 514 460 56 300 25 84 1 NPT thread 1 2 NPT thread Top Bottom ...

Page 13: ...ntended as a representative sample of how the control may be wired for a sample application It is the responsibility of the installer to seek professional advice and or install the the system to meet all necessary codes for the jurisdiction of the actual installation Title Notes This is not an engineered drawing and does not necessarily include all the components for an entire system It is intende...

Page 14: ...panel for the first zone 5 Begin filling the system 6 Slowly open the Purging Valve field supplied on the return side of the zone line to let the air out of the system 7 Once the air has been eliminated from the zone close the air purging valve 8 Finally close all the valves to isolate the zone from the panel before moving on to the next zone 9 Repeat this procedure based on the amount of zones on...

Page 15: ...the purchasers sole remedy shall be at Tamas Hydronic Systems Inc s option repair or replacement The foregoing warranties and remedies are exclusive and in lieu of all other warranties expressed or implied either in fact or by operation of law statutory or otherwise including warranties of merchantability and fitness for a particular purpose application Tamas Hydronic Systems Inc neither assumes n...

Page 16: ... Hydronic Systems Tamas Hydronic Systems Inc Phone 1 403 279 0020 4516 112 Avenue SE Fax 1 403 279 0747 Calgary Alberta T2C 2K2 info tamashydronic com TamasHydronicSystems TamasHydronic company tamas hydronic systems ...