WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE 

FOLLOWING: 
●Use this unit in the manner intended by the manufacturer. If you have any questions contact the manufacturer.  
●Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being 
switched on accidentally. When the service disconnect cannot be locked, securely fasten a prominent warning device, such 
as a tag, to the service panel. 
●When cutting or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities. 
●Never place a switch where it can be reached from a tub or shower. 
●Do not use this fan over a tub or shower. 
●Do not use this fan over cooking appliances. 

CAUTION: For General Ventilation Use Only. Do Not Use to Exhaust Hazardous or Explosive Materials and Vapors. 

CAUTION: This unit has an unguarded impeller. Do Not Use in Locations Readily Accessible to People or Animals. 

 

 Material Included  

(1)

 

Infinity 2200 (with 6’ line cord) 

(1)  4 wire patch cable (attached) 
(1) Hanger/Install Kit Containing: 
     (2) Mounting Bracket 5"L 
     (4) Screw, Wood  12 x 1-1/2 
     (4) Screw 10-32 x 1” PH 
     (4) Nut 10-32 w/Nylon Insert  
     (8) Washer 1/4" Flat 
     (4) Washer #10 Flat 

Tools and Supplied Needed (not provided) 

 

Screw Gun with Phillips Head Bit 

 

Measuring Tape 

 

Utility Knife 

 

Jig Saw 

(to create holes for external hoods) 

 

Drywall Hand Saw 

 

4 Lengths of 10" Diameter Duct (Flexible or Rigid) 

Measure to 

determine length requirements for the installation 

 

Duct Aluminum Tape or 10" Strap Band/Clamp 

(to affix duct) 

 

Siding Materials (shingles, flashing etc.) 

 

(2) External 10" Vents/Hoods (sold separately) 

 

 

 

 

 

20 Patterson Brook Rd / West Wareham, MA 02576 

774-678-4433 / 800-222-5932 / Fax 774-678-4436

 

 

Summary of Contents for Infinity 2200

Page 1: ...r shower Do not use this fan over a tub or shower Do not use this fan over cooking appliances CAUTION For General Ventilation Use Only Do Not Use to Exhaust Hazardous or Explosive Materials and Vapors CAUTION This unit has an unguarded impeller Do Not Use in Locations Readily Accessible to People or Animals Material Included 1 Infinity 2200 with 6 line cord 1 4 wire patch cable attached 1 Hanger I...

Page 2: ... ceiling can be installed above hallways or rooms in desired locations It is recommended that the supply and exhaust registers in the drywall ceiling be no less than six feet apart for proper air exchange External vents should be installed on opposite sides of the home to prevent recirculation of exhausted air The intake and exhaust hoods are intended to be installed in the vertical walls of the a...

Page 3: ... 4 D Mounting Flange Dimensions 27 1 4 x 1 1 2 Duct Size 4 10 Duct Collar Length 3 with Bead Electrical Requirements 115V 60 Hz 3A Total Power 336 Watts Air Flow Each motor 1070 cfm 1 Wg Unit Weight 27 lbs Shipping Carton 31 x 19 x 11 Shipping Weight 33lbs ...

Page 4: ...D BY ASSOCIATED EQUIPMENT FURNACES SOLARIA ETC FROM REPAIRS OR MODIFICATIONS ATTEMPTED BY PERSONS OTHER THAN TAMARACK TECHNOLOGIES INC FROM ABUSE ACCIDENTAL OR SHIPPING DAMAGE OR ACTS OF GOD THIS WARRANTY DOES NOT APPLY TO THE PRODUCT USED OUTSIDE THE UNITED STATES ITS TERRITORIAL POSSESSIONS AND CANADA EXCEPT AS SET FORTH ABOVE NO EXPRESS OR IMPLIED WARRANTY IS GIVEN OR AUTHORIZED BY TAMARACK TEC...

Reviews: