background image

                                                                                                                                                                     

20 Patterson Book Rd. Suite 7 

             

                                                               

West Wareham, MA 02576 

                                                  

                             

              

774-678-4433 / 800-222-5932 

                                                                                                                             [email protected] 

 

 

 

READ AND SAVE THESE INSTRUCTIONS 

 

Serial Number: ______________________

 

 

Date of Purchase: ____________________ 

 

Point of Purchase: ___________________

 

 

The serial number is located on the shipping 

carton and on a label affixed to an insulated 

door. 

 

 

Unpacking your HV3400: 

 

When you have unpacked your HV3400 carefully 

you will find the following:

 

 

One (1) HV3400 

One (1) White Metal Grille w/ (6) Screws  

Two (2) Handheld Remote Transmitters 

One (1) Remote Receiver w/ line cord & interconnect 

cable

 

 

 

The Best Location for your HV3400: 

The HV3400 should be installed in your attic in a central 

location within your home. Above a central hallway or at the top of a stairwell will provide the best 

airflow.

 

 

Make sure that there aren’t any pipes, wires, rafters or air conditioning or heating ducts 

running through the space where the HV3400 will be installed. The HV3400 must be 

installed vertically. 

 

 

Make sure that you have adequate exhaust area out of your attic. This can be accomplished with

 

a combination of roof, ridge, or gable end vents. The HV3400 requires a minimum of 4.5 square feet of attic 

exhaust area.

 

 

If your home has an a 

 

 

truss roofing system, care should be taken that the HV3400 will fit within the truss layout.

 

WARNING: 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

 

 

Use this unit in the manner intended by the manufacturer. If you have any questions, contact the 

manufacturer. Before

 

 When 

servicing or cleaning unit; switch power off at service panel and lock service panel to 

prevent power from being switched on accidentally. When the service panel cannot be locked, 

securely fasten a prominent warning device, such as a tag, to the service panel.

 

 Never place a switch where it can be reached from a tub or shower.

 

 

Do not use this fan over a tub or shower.

 

Do not use this fan over cooking appliances.

 

WARNING: 

To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control 

device. 

CAUTION: For general ventilation use only. Do not use to exhaust hazardous or explosive materials and 

vapors. CAUTION: This unit has an unguarded impeller. Do not use in locations readily accessible to people or 

animals. 

 

HV3400

 

HV.13

 

WHOLE HOUSE VENTILATOR

 

PRODUCT MANUAL &  INSTALLATION  GUIDE

 

Summary of Contents for HV3400

Page 1: ...h a combination of roof ridge or gable end vents The HV3400 requires a minimum of 4 5 square feet of attic exhaust area If your home has an a truss roofing system care should be taken that the HV3400 will fitwithin the truss layout WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Use this unit in the manner intended by the manufacturer If you have any qu...

Page 2: ...g or other hidden utilities 3 Install a foam weather stripping or other flexible material not supplied on top of the joists and added framing This will serve to seal between the housing and the framing as well as dampen vibrations Check the joint between the and the 2x stock Some types of ceilings are spaced away from the joists Any gap between the 2x s and the ceiling should be sealed prior to fi...

Page 3: ...n B and controls the speed of the fan Buttons C D are not used See the wiring section below for more details 6 Rotate the upper housing until it lines up with the lower housing Make sure the edges of the two housings mate all the way around the HV3400 figure 6 and then pull the black attachment handles down over their attachment posts Figure 7 7 If desired secure the HV3400 to the top of the joist...

Page 4: ...subject to the following conditions exclusions and limitations THE WARRANTY DOES NOT COVER PROBLEMS RESULTING FROM INSTALLATION OPERATION OR MAINTENANCE THAT HAS BEEN UNDERTAKEN OTHER THAN IN ACCORDANCE WITH THE INSTRUCTIONS THIS WARRANTY DOES NOT COVER PROBLEMS RESULTING FROM DEFECTS IN OR CAUSED BY ASSOCIATED EQUIPMENT FURNACES SOLARIA ETC FROM REPAIRS OR MODIFICATIONS ATTEMPTED BY PERSONS OTHER...