background image

metaSETZ TLC-8D 

Tally controller for the NewTek TriCaster

TM 

 

 

 

TriCaster Compatibility 
 
The TLC-D controllers are compatible with TriCaster 410, 450, 455, 460, 850, 855, 860 and 8000. It is also 
compatible with the NewTek IP Series VMC1 and VMC1 IN. It is not compatible with the TriCaster 40 or 
TriCaster Mini. 
 
Connecting to the TriCaster 
 
The 8D controller is powered via the supplied USB cable. Plug this into any available USB port on your 
TriCaster. Since the cable is only for power you can alternately use a USB power cube to free up a port 
on your TriCaster. Also connect the supplied 15 pin cable between the tally ports on the TriCaster and 
the TLC-8D. 
 
Connecting the Tally Lights 
 
The TLC-8D controller has eight tally ports. These ports correspond to the first eight switcher inputs on 
your TriCaster. Tally lights can be connected via standard (user supplied) Ethernet style cable such as 
Cat3, Cat5 or Cat6 with RJ45 connectors. The tally light system has been tested with up to 1000 ft. 
(304m) but longer cable runs may pick up noise in the intercom lines. 
 
All metaSETZ tally controllers are compatible with all (properly configured) metaSETZ tally lights see the 
tally light manual for details on the jumper settings. TL-1, TL-XD, TL-2 tally lights and RU-2 relay units can 
be intermixed freely. Due to limitations of the TriCaster’s 15 pin tally port only the two red LEDs will 
function on the tally light. 
  
Note: While the metaSETZ tally system uses Ethernet style cable because of its low cost and general 
availability, the devices are not Ethernet based and should never be interconnected with actual 
networking equipment. Connecting to any such equipment can damage the network hardware or your 
tally system and is not covered under our warranty. 

 
 