Takex PIR-T40NAM Instruction Manual Download Page 1

PIR-T40NAM (W) is passive infrared sensor that detects far-infrared rays emitted from the human body and outputs a contact signal. 
Since this unit significantly reduces lost and false detection using the unique triple mirror and signal processing systems, it can be 
used both for indoor and outdoor applications. This unit has the following features suitable for multiple applications.
• Detection distance up to 115’(40m)

Max 150'(45m) with high density mode

• Detection distance and direction adjustable
• Mounting height of 6.6’ to 13’(2 to 4m) for normal operation (max. 20’(6m) in specialized operation modes)
• Equipped with N.C. contact output for security and N.O. contact output for activation of ancillary devices
• Can be mounted on wall surfaces, as well as on poles, ceilings, and under eaves using the optional accessories (sold separately)
• Equipped with anti-masking and back tamper functions for more secure protection

[Cover unit]

Memory LED

: Red (embedded)

Alarm LED

: Red (embedded) 

Cover locking screw

Wiring hole for 
exposed wiring

(Knockout)

Wiring hole

(with grommet)

Back tamper

[Sensor unit]

Mode setting
table

Area setting
table

Mode selector

Indicator

Area selector

Alignment 
lever

[Mirror unit]

Terminal block

Wiring hole

(with grommet)

Mirror 
locking screw

Accessories

Tapping screw

φ

4×30

(4 pcs)

Instruction

manual

This document

Area masking sheet

(1 sheet)

Anti bird spike

(3 pcs)

Thank you for purchasing this product.
Before using the product, please read this instruction manual to ensure correct operation.

TRIPLE MIRROR PASSIVE SENSOR

Instruction Manual

PIR-T40NAM (W)

1

PRODUCT DESCRIPTION

2

PARTS DESCRIPTION

Wiring hole for 
exposed wiring

(Knockout)

(Vertical curtain protection) 

Summary of Contents for PIR-T40NAM

Page 1: ...ces as well as on poles ceilings and under eaves using the optional accessories sold separately Equipped with anti masking and back tamper functions for more secure protection Cover unit Memory LED Re...

Page 2: ...and or electric shock P OPU JOTUBMM UIF VOJU JO QMBDFT TVCKFDU UP PJM TNPLF TUFBN high humidity and or a lot of dust Electricity transmitted through oil water and or dust may result in fire electric...

Page 3: ...that it does not cover the wall surface It may cause false or lost detection Move the detection area horizontally by one step or more to keep it away from the wall Adjust the detection area so that it...

Page 4: ...eet in order from the longest part of the detection area and adjust the detection distance Near detection area When detection of nearer area is required remove Area masking plate stored inside so that...

Page 5: ...arting output on the right Be careful not to cross the wires 5 INSTALLATION Pole attachment BP 32 Ceiling attachment KP 32 Pole attachment BP 32 1ft 30cm For open wiring break the knockout on the rear...

Page 6: ...vel supplied to the sensor decreases abnormally to approx 8 5V or less Alarm is issued using alarm output and alarm LED before the sensor operation becomes unstable It works even during the warming up...

Page 7: ...p OFF Blinking Factory set DIP switch 2 Memory LED operation setting 2 of mode selector 2 This setting is used to set the blinking operation of the memory LED red This can be set only when DIP switch...

Page 8: ...LED Red Alarm LED Red 0 5 sec 0 5 sec 0 5 sec 0 15 sec 0 15 sec 0 15 sec 0 15 sec 0 6 sec 0 1 sec 0 1 sec Description of LED operation Factory set ON OFF DIP Switch 1 1 2 3 4 5 6 7 8 DIP Switch 2 ON O...

Page 9: ...ear unlit when standing outside of the detection area Detection distance fine adjustment using LED area checker Alignment lever Slide the alignment lever to the right and latch it Red Green Red Green...

Page 10: ...y with dust or water 3 Detection distance is inappropriate 4 Temperature difference between the human body and surrounding area is small 1 Set the detection area again 2 Wipe off dirt using a soft dry...

Page 11: ...25A resistive load built in contact protective resistor 3 3 Dry mechanical contact N C Continuous output 24V AC DC 0 1A resistive load built in contact protective resistor 3 3 Blinks during warm up Li...

Page 12: ...iginal date of shipment During the Warranty Period TAKEX will repair or replace at its sole option free of charge any defective parts returned prepaid Please provide the model number of the products o...

Reviews: