background image

Alarm indicator
[Used for both alarm/memory]
(Red LED)

Environmental indicator
(Orange LED)

Microphone

Lock screw

Knockout

Tamper switch

Terminal block

Indicator

Area selector

Mode selector

Check mode switch

Sensor unit

Base unit

Accessories

Tapping screw

φ

4×30 (mm)

-2

Instruction manual

(This document) -1

Front mark

3

PRECAUTIONS

The following precautions should be observed by categorizing the degree of hazard or damage that would occur due to improper use.

Be sure to observe

We explain the precautions you should observe using the following symbols throughout the manual.

Warning

Caution

Indicates situations that may result in death or 
serious injury.

Indicates situations that may result in minor injury and/or 
damage to property, or delayed notification in the 
operating system due to malfunctions and/or alarm failure.

An action you must perform, 
or description we would like you to understand. 

A prohibited action you must not do.

If the following errors or malfunctions occur, immediately cut the power 
supply and contact the dealer.  Failure to follow this may result in fire, 
electric shock, and/or malfunction.
• Smoke, abnormal odor and/or sound are generated
• Liquid such as water and/or foreign materials has entered inside the unit
• Deformed and/or damaged parts have been discovered in the unit

Warning

Do not disassemble or remodel the unit.  Failure to follow this may 
result in fire, electric shock, and/or malfunction.

Install the unit on solid places, such as ceiling surfaces or walls with 
reinforced materials applied. When you install the unit on materials 
other than wood, such as plasterboard or concrete, use the anchors and 
mounting screws appropriate to the wall materials, and install the unit 
securely. Unstable installation may result in injury or damage to 
property if the unit falls down.

Fix the sensor unit for operation using the lock screws. This prevents 
injury and/or damage to property if the unit falls down, and also 
prevents the unit from being scratched and/or tarnished.

Do not use the unit outside the specified range of power voltage. Failure 
to follow this may result in fire, electric shock, and/or malfunction.

Do not connect devices with a capacity exceeding that indicated by the 
output contacts on the unit. This may result in electric shock, fire, 
and/or malfunction.

Do not touch the terminals with wet hands. Failure to follow this may 
result in electric shock.

Do not install the unit in a place and/or with a mounting method that 
cannot support its weight.  Failure to follow this may result in injury or 
damage to property if the unit falls down.

Instruction Manual

1

PRODUCT DESCRIPTION

GS-2000E

GLASS BREAK SENSOR

Thank you for purchasing our product.
Before using this product, please read this instruction manual to ensure correct operation.

This product is a non-contact sensor that detects the breaking sound (ultrasonic bandwidth) generated when plate glass, used for a 
window or showcase, gets broken on impact, and will output an alarm.  By adopting a circuit that detects two kinds of ultrasonic 
bands, the breaking sound of glass can be detected.
This sensor is a passive type, and can be installed together with multiple units in the same location. Its slim body is inconspicuous, 
allowing the unit to be used in various places. Ensure that this sensor is used for security in unmanned spaces only.

2

PARTS DESCRIPTION

Summary of Contents for GS-2000E

Page 1: ... wood such as plasterboard or concrete use the anchors and mounting screws appropriate to the wall materials and install the unit securely Unstable installation may result in injury or damage to property if the unit falls down Fix the sensor unit for operation using the lock screws This prevents injury and or damage to property if the unit falls down and also prevents the unit from being scratched...

Page 2: ... breaking sound generated when plate glass is broken on impact It cannot detect broken glass damaged by a force other than impact such as deformation of buildings structures Caution Do not apply impact to the unit Applying strong impact to the unit may result in deteriorated performance and or damage to the unit Install the sensor at a place where the glass surface to be guarded can be seen direct...

Page 3: ...ront direction Sensor mounting position For open wiring before mounting the base unit break the knockout on the base unit and pass the wire through the opening Mount the sensor max two meters from the glass surface In a curtain box mount the sensor so that the operation area is not blocked Do not mount the sensor in a curtain box that is too deep to avoid masking the protection area Mount the sens...

Page 4: ...s Maximum allowable wiring distance between the sensor and power equipment Basic connection connection example when using multiple units Distance between wall and sensor Distance between ceiling and center of glass Area adjustment angle from 0 to 30 Center of the area Area selector Indicator Front mark 0 30 The detection area has a spread Set the area so that the center of the detection area is ro...

Page 5: ...f a warning is given immediately check operation of the sensor Check mode Operation mode This mode is used to check the installation environment and the sensitivity Press the check mode switch to activate Check mode for approximately five minutes While in this mode the alarm indicator red blinks at short intervals In this mode both the environmental indicator orange and alarm indicator red can be ...

Page 6: ...nsor unit from the glass surface to be protected and check the sensitivity Check it from all the positions of the glass surface to be protected Note Reliable use of the glass checker is difficult under the influence of adverse reflection from ceilings walls and or floors If this is the case move the glass checker position slightly to the left or right and check again If only the environmental indi...

Page 7: ...oltage 2 Remove the blocking materials 3 Set the appropriate sensitivity Refer to 8 Function Description The unit remains in check mode not switching to operation mode 1 There are noise sources bells ultrasonic sensors printers or devices that generate metallic sound near the unit 1 Remove items causing malfunction or keep them apart from the unit three meters or more The unit sometimes does not o...

Page 8: ... shipment During the Warranty Period TAKEX will repair or replace at its sole option free of charge any defective parts returned prepaid Please provide the model number of the products original date of shipment and nature of difficulty being experienced There will be charges rendered for product repairs made after our Warranty Period has expired No 05 991 1708 In Japan Takex America Inc 4 15 Howle...

Reviews: