TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original date of shipment. Our warranty does not cover
damage or failure caused by natural disasters, abuse, misuse, abnormal usage, faulty installation, improper maintenance or any repairs other than those
provided by TAKEX. All implied warranties with respect to TAKEX, including implied warranties for merchantability and implied warranties for fitness, are
limited in duration to 12 months from original date of shipment. During the Warranty Period, TAKEX will repair or replace, at its sole option,free of charge, any
defective parts returned prepaid. Please provide the model number of the products, original date of shipment and nature of difficulty being experienced. There
will be charges rendered for product repairs made after our Warranty Period has expired.
No.05-316 B9035
In Japan
Takex America Inc.
Takenaka Engineering Co., Ltd.
https : // www. takex-eng. co. jp /
Takex America Inc.
https : // www. takex. com
Takex Europe Ltd.
https : // www. takex. com
In the U.S.
In the U.K.
In Australia
Aviary Court, Wade Road,
Basingstoke, Hampshire. RG24 8PE, U.K.
Tel : (+44) 01256-475555
Fax : (+44) 01256-466268
4/15 Howleys Road, Notting Hill,
VIC, 3168
Tel : +61 (03) 9544-2477
Fax : +61 (03) 9543-2342
https : // www. takex. com
83-1, Gojo-Dori, Sotokan Nishi-iru, Higashino,
Yamashina-ku, Kyoto 607-8156, Japan
Tel : 81-75-501-6651
Fax : 81-75-593-3816
151, San Zeno WAY
Sunnyvale, CA 94086, USA
Tel : 408-747-0100
Fax : 408-734-1100
Instruction Manual
1
PRODUCT DESCRIPTION
2
PARTS DESCRIPTION
3
DO'S AND DON'T'S
GS-1100E
GLASS BREAK SENSOR
Thank you for purchasing the TAKEX product. This sensor will provide long and dependable service when properly installed.
Please read this Instruction Manual carefully for correct and effective use.
Note : This sensor is designed to detect intrusion and to initiate an alarm ; it is not a burglary-preventing device.
TAKEX is not responsible for damage or losses caused by accident, theft, Acts of God (including inductive lightning),
abuse, misuse, abnormal usage, faulty installation or improper maintenance.
Exposed wiring hole
(Knockout)
Microphone holder
Mode switch
(Factory set : “Operation mode”)
Wire lead
(for exposed wiring)
Alarm LED
(Red)
* Lights up during an alarm.
* Displays the alarm memory.
Recessed wiring hole
(Knockout)
Mounting hole
Detection microphone
Cover
Cover locking screw
Sensitivity volume
* Enables the sensitivity to
be adjusted according to
the installation
environment.
(Factory set : “mid”)
Environmental LED
(Orange)
* Functions during check
mode only.
Tamper switch
Terminals
Exposed wiring hole
(Knockout)
Corner mounting hole
(Knockout)
GS-1100E is an ultrasonic sensor designed to detect the sound of breaking glass such as plate glass windows, doors, showcases etc.
●
This unit is designed to detect the sound given
when glass is broken due to impact.
If glass is broken due to stress or other means this
may not be detected.
●
Use of input voltage exceeding specifications may
result in fire.
●
Use of equipment exceeding contact capacity of
30V (AC/DC) may result in fire.
●
Unit should not be disassembled or modified due
to risk of electric shock or fire hazard.
●
Do not drop unit or subject to hard knocks.
●
Liquids, metallic and inflammable materials
should not be allowed to enter the unit.
Precautions for use
●
Unit is designed for Indoor use only.
●
Unit is designed for use in an enclosed environment only.
●
Do not install in an environment subject to electrical noise or intense
vibration.
●
Do not install in an environment subject to smoke, steam, excessive
humidity or dust.
●
Do not install near products generating ultrasonic noise, such as 'bell'
telephones, printers, air conditioning vents, or in environments
generating similar ultrasonic sounds.
●
Do not use in environments with poorly fitted window panes.
●
Unit is designed for unmanned (vacant) protection only.
Alarms may be generated in the case of ultrasonic sounds artificially
generated.
●
Ensure target to be protected is within protection area.
(Horizontal: 8m (26') Max. Vertical : 7m (23') Max.)
Precautions on installation
Tapping screw
φ
3
×
30:2pcs
Accessory
10
EXTERNAL DIMENSIONS
9
SPECIFICATIONS
Model
Detection system
Coverage
Angle adjustment
Power voltage
Current consumption
Alarm output
Alarm LED
Alarm memory
Tamper signal
Environmental LED
Ambient temperature range
Mounting position
Wiring
Weight
Appearance
GS-1100E
Ultrasonic microphone
Horizontal : 8m (26') max. Vertical : 7m (23') max.
(plate glass of 400 square cm or more, one side 20cm)
Horizontally
±
40
°
9V to 30V DC (non-polarity)
30mA or less
Dry contact relay N.C. Reset : Approx. 2 sec.
30V (AC/DC) 0.1A or less
Red LED lights at alarm
Alarm LED is flickering for 3 min., lighting for 47 min.
and then automatically reset at detection.
Dry contact relay N.C.
Orange LED Light at bad environments
(at check mode)
−
10
°
C to
+
50
°
C (
+
14
°
F to
+
122
°
F )
Indoor (wall)
Terminals
120g (3.86oz)
Resin (White)
This sensor is designed to detect breaking sound of plate glass with
a shock.
Note that glass breaking without a shock (glass breaking caused by
distortion of building) may cause undetection.
70mm
32mm
110mm
[BACK VIEW]
(1.26")
(2.76")
(4.33"
)
Corner
Mounting
Hole
Mounting Hole
83.5mm(3.29")
76mm(3")
Recessed
Wiring Hole
Exposed
Wiring Hole
8
TROUBLESHOOTING
Analyze possible problems according to the following table .
If normal operation cannot be restored by this means, contact either the dealer from
whom you bought the unit or TAKEX.
Trouble
Completely inactive.
Frequent alarm with
no detection.
(alarm LED often lights.)
Control panel is inactive
though LED works normally.
Possible cause
No power supply.
Check power and wiring.
Sensitivity too low.
Set sensitivity to midium and recheck.
Keep distance 3m or more from the noise source.
Set sensitivity lower and perform operation
check 6.
Change installation site.
Change path of wiring.
Check wiring with tester and remove the cause.
Adjust to proper voltage.
There is noise making source nearby such as bell,
ultrasonic sensor, etc.
There is an electrical noise source such as power
source or its wiring is located nearby.
Improper power voltage.
Broken/improper wiring of signal line.
Remedy