Using in Series/Parallel Operation
133
Calibrating Slave Unit Output Settings
Calibrate the Slave unit to match the Slave’s output voltage in series operation with the Master’s voltage.
Preparation
The following measuring device is required for calibration.
Voltage Measuring Digital Multimeter
2 devices
No. of Display Digits: 5 1/2 or more Display Accuracy : 0.005% or more
* (30V/60V Type
:
Equipped with a measuring range from 1mV to 100V)
(500V Type
:
Equipped with a measuring range from 1mV to 1000V)
Offset/Full Scale Calibration of Slave Unit Output Voltage
1. Disconnect the load wires and the remote sensing
wires. Connect the digital multimeter to the output
terminal of the Master and the Slave respectively.
Turn the POWER switch ON and OUTPUT OFF in
advance.
+
-
V
+
-
+
-
V
+
-
Slave Unit
Master
Digital Multimeter
Digital Multimeter
2. At the Master, set the constant voltage setting
value to [ xV ] and the constant current setting
value to [ yA ] and set the output to ON.
30V Type
60V Type
500V Type
[xV]
0.01V
0.01V
0.1V
[yA]
1.0A
1.0A
0.1A
120V Type
400V Type
[xV]
0.1V
0.1V
[yA]
0.1A
0.1A
On how to set, see Operating as Constant Voltage
Power Supply under Basic Operations.(page28)
3. Press the FUNC. key of the Slave.
4. Turn the VOLTAGE dial of the Slave unit to display
the setting item number 37 in the Number Display
(voltage).
* At that time, turn off the Number Display (current).
5. Adjust the CURRENT dial of the Slave so that the
display of the digital multimeter for output voltage
measurement is the same as the display of the
digital multimeter for output voltage measurement.
6. Press the FUNC. key of the Slave unit to set the
offset calibration value of output voltage setting.
7. At the Master, set the constant voltage setting
value to [ xV ] and the constant current setting
value to [ yA ] and set the output to ON.
30V Type
60V Type
500V Type
[xV]
30.00V
60.00V
500.0V
[yA]
1.0A
1.0A
0.1A
120V Type
400V Type
[xV]
120.0V
400.0V
[yA]
1.0A
0.1A
On how to set, see Operating as Constant Voltage
Power Supply under Basic Operations. (Page
Summary of Contents for HX-S-G2 Series
Page 165: ...Special Loads 165 This page is blank...
Page 169: ...Maintenance 169 This page is blank...
Page 211: ...Specifications 211 External Diagrams 1 HX S 030 200G2 F I...
Page 212: ...Specifications 212 2 HX S 030 400G2 F I...
Page 213: ...Specifications 213 3 HX S 060 100G2 F I...
Page 214: ...Specifications 214 4 HX S 060 200G2 F I...
Page 215: ...Specifications 215 5 HX S 0120 50G2 F I...
Page 216: ...Specifications 216 6 HX S 0120 100G2 F I...
Page 217: ...Specifications 217 7 HX S 0400 15G2 F I...
Page 218: ...Specifications 218 8 HX S 0400 30G2 F I...
Page 219: ...Specifications 219 9 HX S 0500 12G2 F I...
Page 220: ...Specifications 220 10 HX S 0500 24G2 F I...
Page 221: ...Specifications 221 11 HX S 01000 6G2 F I...
Page 222: ...Specifications 222 12 HX S 01000 12G2 F I...
Page 223: ...Specifications 223...
Page 239: ......