background image

1

Version 6

2022.09

The precautions listed here are to ensure that YUME SWING can be installed safely, and to prevent any danger or risk to the person installing 

YUME SWING or those around them. All of these precautions are important for safety. Takara Belmont is not responsible for any damage or risk 

  to the person installing YUME SWING or those around them due to accidents if YUME SWING is installed without adhering to the precautions.

If YUME SWING is installed after ignoring this symbol, “there is the risk of light or moderate injury or physical damage”.

Table of Contents

Before Installation 

2

1  Overall Layout Diagram

2

2  Product Fixing Position

5

3  Installation Conditions 

8

Usage Conditions 

9

Name of Parts 

10

Contents of Packaging 

11

Carrying the Product 

15

Installation of the Product 

16

1   Check the Position of Mirror and Cabinet 17

2  Installation of SWING

 

Arm

17

3  Installation of Caster Rail

19

4  Installation of Basin Unit

23

5  Plumbing 

25

6  Installation of Chair 

27

7   Adjustment of Center of Basin Unit and Chair 28

8  Checking after Plumbing

30

9   Installation of Base Front Cover 31

10 Installation of Rotation Arm Cover 31

11 Installation of Maintenance Cover 32

12 Installation of Caster Cover

32

13 Installation of Plumbing Cover

33

After Installation 

34

Installation of Neck Cushion

34

Yume Swing (Reverse Slide Layout Spec.)

Basin Unit

EX-YMSBXYM2 (YUME Basin, Reverse Slide Spec.)

EA-YMSPK2 (Wall mounted plumbing)
EA-YMSPY2 (Under the floor plumbing) 

SWING Arm

EX-YMSAF2 (Front Layout, Reverse Slide Spec.)
EX-YMSAR2 (Rear Layout, Reverse Slide Spec.)

(Image is of EX-YMSBXYM2/EX-YMSAR2/EA-YMSPY2)

Caution

To the clients

Clients must ask professional to install YUME SWING.

Clients must not install YUME SWING by themselves. 

Clients must store these manuals in a safe place so as not to lose them. 

To the installer

The manuals should be thoroughly read and understood before installation to ensure 

    that YUME SWING is installed correctly. 

After installation, give these instructions to the client. 

*The actual shape of YUME SWING, the images and dimensions listed in these manuals may be modified 

 and are subject to change without notice. 

YUME SWING

for Reverse Slide Layout

Installation Manual

Basin Unit

SWING Arm

Plumbing Cover

Plumbing Cover

EA-YMSPU2 (Above the floor plumbing)

MEMO

35

Summary of Contents for YUME SWING

Page 1: ...er Plumbing 30 9 Installation of Base Front Cover 31 10 Installation of Rotation Arm Cover 31 11 Installation of Maintenance Cover 32 12 Installation of Caster Cover 32 13 Installation of Plumbing Cov...

Page 2: ...base Mirror center line Drain VU VP40 H 140 Plumbing cover Water supply Rc1 2 13m m H 90 In case of Under the floor plumbing A Edge of fixing base Caster rail F Rotation center Hot water supply Rc1 2...

Page 3: ...g on the type of chair using with YUME SWING Check the dimensions from the list as shown below dimensions are for reference Basin Unit Height of neck fittings 1 EX YMSBXYM2 YUME Basin 774 Wall mounted...

Page 4: ...ing construction diagram 50 40 45 Drain pipe Water supply Hot water supply wall Cabinet Above the floor plumbing Diagonal line Be sure to use the plumbing cover for Above the floor plumbing 377 60 40...

Page 5: ...ition In the case that space between wall and chair center is In case of wall mounting or using more than 1 unit from edge of Yume Swing basin to edge of fixing base Perforations Edge of fixing base F...

Page 6: ...olt anchor fixed position 254 Wall From wall to edge of fixing base In case that dimension is 254 In case of YUME Basin From basin rear cover to wall 86 Note Be sure to have 50mm or more between the b...

Page 7: ...Arm rotation center line Arm rotation center line Fixingbase Please note that this is a template for the standard slide layout and not for the reverse slide layout However you can use this as a templ...

Page 8: ...nd a connection of pipes by caulking material etc Request measures to prevent water leakage under the floor and downstairs Raised pipe dimension Raise dimensions Hot water supply Drain Under the floor...

Page 9: ...use steam with the hot water supply 9 Always connect hot water and water supply pipes after removing all contaminants such as dirt sand and oil Failure to follow this instruction may cause problem Ens...

Page 10: ...er supply pipe Gasket Check valve Maintenance cover Gasket Nipple Flexible pipe Stop valve Drain hose Main unit drain hose PVC 90 elbow pipe PVC pipe Plumbing cover Rotation arm Fixing base Drain Show...

Page 11: ...until starting plumbing installation Before installation check if all of the below parts is coming with the product Caution Accessories Drain cap 1 Mohair tape Manual Haircatcher 1 Head pillows 1 pai...

Page 12: ...Packing size and weight Basin Unit YUME Basin Basin unit 37kg Wood frame 30kg Unit mm 852 106 595 650 821 1028 5 922 5 12...

Page 13: ...ain hose gasket big x 2 small x 1 Operating manual Installation manual this manual Common parts for YUME Basin and Side Basin Packing size and weight SWING Arm Front Layout Rear Layout Rotation arm 19...

Page 14: ...the floor plumbing Contents of Packaging Under the floor plumbing Wall mounted plumbing Above the floor plumbing Unit mm Paper Template Paper template is supplied separately Refer to pages 5 to 7 For...

Page 15: ...over hot water water pipes or drain pipe Always have two people to carry it Caution Caution Caution Do not lose the Urea screws holding down the maintenance cover The Urea screws are used for holding...

Page 16: ...n manual supplied with each chair 7 Adjustment of Center of Basin Unit and Chair 8 Checking after Plumbing 9 Installation of Base Front Cover 10 Installation of Rotation Arm Cover 11 Installation of M...

Page 17: ...ing the rotation arm cover fixing base can not be fixed on the floor The screws of rotation arm cover screw with gasket M5 x 12 x 5 pcs will be used when attaching it again so please pay attention not...

Page 18: ...as around the pipes so that there are no gaps in order to prevent condensation within the basin unit and inside of the SWING arm or water seeping on the floor in the event of water leaks If plumbing g...

Page 19: ...mportant The following process 2 differs depending on the floor material Do the appropriate process Wooden floor Refer to page 20 Drill holes on the attachment position of the caster rail Other than w...

Page 20: ...s on the caster rail attachment position 1 Insert the caster rail under the rotation arm and set to the paper template position Hairline surface to be placed upward Hairline surface of caster rail to...

Page 21: ...d upward Hairline surface of caster rail to be placed upward Other than wooden floor 5 Drill a hole on part 6 Loosen the tapping of move the caster rail slightly and hammer the anchor bearing 7 Return...

Page 22: ...There is a risk of hand injury in burr Fix the caster rail to the floor with screws 1 Insert the caster rail under the rotation arm 2 Fix the caster rail on the floor with 8 pcs of tapping 5 x 30 When...

Page 23: ...m be sure that it does not pinch flexible pipe of the hot water water pipes Install the basin unit while holding up the 2 pcs of flexible pipes 1 Set the basin unit to the position of hexagon screws a...

Page 24: ...page 29 When installing the basin unit on rotation arm pay attention to make the back side of the base and rotation arm shown in gray color in the below illustration to face the same side Failure to...

Page 25: ...is no water leakage from the joint parts 5 1 2 Connecting the water hot water pipes 1 Install the stop valve to raised hot water water pipes Fix it with seal tape and raised hot water water pipes 2 I...

Page 26: ...rain pipe to PVC 90 elbow pipe Be sure to glue it with PVC adhesion bond Do not connect hot water and water in reverse Check if there is no water leakage from the joint part 5 2 2 Connection of the wa...

Page 27: ...in unit hold the basin with hands at around the area of initial position and shampooing position and lock the unit gently If the basin unit is attached to lock points swiftly it may result in product...

Page 28: ...e attached Chair base and lower cover Visible position when rotating and locking the chair Lower cover Chair base Seal Stick the seal on the position that chair is rotated and locked Adjusting the pos...

Page 29: ...hole at the clockwise and anti clockwise direction for adjusting the basin unit The holes are covered by seal Remove the seal and use the holes as necessary When installing the basin unit to rotation...

Page 30: ...shower head Contents of defect Presumed cause Countermeasures How to adjust faulty temperature regulation Test water flow Connect a pressure reducing valve Optional on the upper side mixer side of the...

Page 31: ...2 Secure the base front cover with 2 pcs of screws M6 x 20 with resin washer Install the base front cover to basin unit 1 Install the rotation arm cover to rotation arm 2 Secure the rotation arm cover...

Page 32: ...may be difficult to remove the screws when water leakage into the unit occurs When attaching the Urea screw do not use any tools but attach it by hand In the case of using tools resin part may get br...

Page 33: ...ara Belmont directly Note Using the proper plumbing cover according to each type of plumbing Install the plumbing cover according to the following plumbing types Caution Caution Screw M5 x 15 Neck cus...

Page 34: ...on Snap buttons Fixing pins Basin side Chair side Metal fittings Snap buttons Snap buttons Head pillow Back side Short side comes to basin side Long side comes to chair side Be sure to execute the ins...

Page 35: ...35 MEMO...

Page 36: ...36 1E04RLC0 1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan Printed in Japan TAKARA BELMONT CORPORATION TEL 81 6 6213 5945 FAX 81 6 6212 3680...

Reviews: