background image

11

Nozzle Arch Setup

Remove the drain cap from the drainage 

outlet in the basin

The drain cap should be placed outside the 
basin.

Attach the nozzle arch

Insert the base rubber of the nozzle arch to 
the drainage outlet in the basin.

CAUTION

Be sure to keep the customer’s 
hair from being caught.

Avoid contact of the nozzle 
arch with the customer.

Do not hold the nozzle cover 
because this may lead to 
damage.

Drain cap

Drainage 

outlet

Nozzle arch

Base rubber

Check that the 

nozzle arch is tilted 

towards the front.

Hold the shower head with a rubber band

(i) Switch the shower head to shower mode.

The amount of hot water output in 

low-splash foaming mode is not sufficient 

for cascades of water, and the head bath 

sensation may not be obtained.

(ii) Insert the shower head into the rubber 

holder while holding the rubber band 

towards the customer side.

(iii) Return the rubber band to hold the 

shower head.

Press the convex side of 
the switch to change to 
shower mode.

CAUTION

If the shower head is not secured 
properly with the rubber band, 
the shower head may become 
displaced and cause hot water to 
splash into the surrounding 
area.

CAUTION

When inserting the shower head 
into the holder, pull the shower 
head straight out before insert-
ing it into the holder. The shower 
hose may break if it is bent 
forcibly.

Nozzle cover

Rubber holder

Shower head

Rubber band

Rubber band

Front side

OASIS basin

OASIS basin

Backwash (YUME) basin / 

Sidewash basin

Backwash (YUME) basin / 

Sidewash basin

Summary of Contents for AY-YHBSS Series

Page 1: ...d to promptly and be sure to read this booklet again when necessary This product is an industrial appliance designed for use by hair and beauty salons Only use this product for its intended purpose Th...

Page 2: ...Accessories 7 Names of Parts 8 Device Setup 9 Customer Setup 10 Nozzle Arch Setup 11 Inner Bowl Setup 12 Performing Treatment 12 After Treatment 15 Maintenance Method 17 Daily Inspection 19 Standard...

Page 3: ...roughly before reading this manual Please be sure to read the Safety Precautions and Precautions for Use carefully and use the product correctly Before using the product Precautions shown on this page...

Page 4: ...of the wash unit is 40 C or below Keep the user s and customer s hands fingers bodies and pieces of clothing away from the moving parts of the product or the area around the moving parts This may cau...

Page 5: ...est of the chair be sure to support the head of the customer with your hand and call out to the customer Consideration for the physical condition of customers The customer s head becomes warm during t...

Page 6: ...egeneration and discolouration Avoid applying heat of 60 C or higher This may result in degeneration and discolouration Avoid the use of mint oil and aroma oils This may result in degeneration and dam...

Page 7: ...Dedicated storage bag with liner Operating Instructions One copy this document Be sure to use the neck cushion of the wash unit Neck cushion must be used as performing treatment without using the nec...

Page 8: ...pecification Backwash YUME basin specification Sidewash basin side neck specification Sidewash basin side neck specification AY YHBYMS AY YHBYMO AY YHBSSS AY YHBSSO AY YHBYMS AY YHBSSS AY YHBYMS2 AY Y...

Page 9: ...not listed as compatible Use of the device with non compatible products may result in injury or device damage YUME YUME DX YUME SWING YUME ESPOIR YUME SUITE YUME NOBLE YUME OASIS full lie flat posture...

Page 10: ...sing the hair or after the spa cleansing process If the hair is not wet the hot water may splash and come into contact with the face and ears Support the head of the customer and gently lower the head...

Page 11: ...ash foaming mode is not sufficient for cascades of water and the head bath sensation may not be obtained ii Insert the shower head into the rubber holder while holding the rubber band towards the cust...

Page 12: ...is tilted towards the front Performing Treatment CAUTION Be sure to use a face towel because hot water may splash the customer s face or simultaneous use of other devices that share the same source o...

Page 13: ...ING When adjusting the temperature of the hot water tilt the nozzle arch towards you and adjust the temperature while checking the temperature with hands so that the hot water does not come into conta...

Page 14: ...ould be discontinued Care must be taken particularly for customers who are susceptible to dizziness from heat who have high blood pressure or have concerns about their physical condition Do not use th...

Page 15: ...wl after water is drained The inner bowl should be stored in the pocket section of the dedicated storage bag See page 16 Remove the shower head and return to the shower head holder Pull the rubber ban...

Page 16: ...Nozzle arch storage Inner bowl Nozzle arch Storage Method Dedicated storage bag The bag is made of waterproof material however it is not designed to hold water Wipe the inside of the bag to prevent an...

Page 17: ...ion Cleaning must be performed if the product is being reused after a period of non use Also be sure to check that the product operates correctly after cleaning Maintenance of Individual Parts CAUTION...

Page 18: ...e rubber holder with the front side facing the rubber holder Front Front Back Back Be sure to install the filter to prevent contamination of the pipes with foreign matter CAUTION i ii ii Filter Rubber...

Page 19: ...local Takara Belmont dealer Discontinue use and contact your local Takara Belmont dealer The rubber band and or the rubber holder may be worn out Discontinue use and contact your local Takara Belmont...

Page 20: ...parts metal parts resin parts etc are not covered under the guarantee Consumable goods the following items are not covered under the guarantee and incur a charge Rubber band Rubber holder Inner bowl...

Page 21: ...sation Temperature 20 C to 70 C Humidity 95 or lower without condensation At least 8 6 L min 2 4 kg YUME YUME DX YUME SWING YUME ESPOIR YUME SUITE YUME NOBLE YUME OASIS full lie flat posture only W SW...

Page 22: ...ension Diagram Unit mm Inner Bowl Nozzle Arch 454 193 YMS SSS SMS2 SSS2 182 YMO SSO 307 109 AY YHBYMS AY YHBYMS AY YHBYM AY YHBYM 5 30 350 YMS YMO 346 SSS SSO 357 YMS2 338 SSS2 599 5 YMS SSS YMS2 597...

Page 23: ...23 Notes...

Page 24: ...24 1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan TEL 81 6 6213 5945 FAX 81 6 6212 3680 TAKARA BELMONT CORPORATION Printed in Japan...

Reviews: