TR
OUBLE
SHOO
TING
TR
OUBLE
SHOO
TING
30 • On-Demand Water Heater Service Handbook for 240, 340 & 540 Condensing Models
WIRING DIAGRAMS
Continued on the next page.
Figure 15
: Wiring Schematic for 240 (T-H3J) and 340 (T-H3S) Models
W: WHITE
R: RED
BK: BLACK
P: PURPLE
LB: LIGHT BLUE
BL: BLUE
G: GREEN
Y: YELLOW
O: ORANGE
BR: BROWN
9
8
7
6
5
4
3
2
1
10
OFF
Temperature remote controller
R
BK
R W
BK
Ground
G
O
W
Y BL
O
R
PCB
W
120 VAC
G
Ground
SW
Ground
W
BK
G
Igniter rod
P
73
53
9
3
OR
G
LB
BL
O.H.C.F.
BL
Hi-
limit
Switch
BL
Gas
Propor-
Valve
W
R
BL
BL
BL
BL
P
BK
BK
W
BK
BK
Outlet thermistor
Inlet thermistor
Surge
box
Hi-limit switch
for exhaust
Exhaust
thermistor
W
W
W
W BK
W
BL R
BK
Temperature controller
Heater
Heater
Heater
240/340 Outdoor
Heater
BK
Bank of DIPswitches
Y
Y
Y
Y
Y
Y
W
W
W
Y
Flame rod
AFR rod
BK
W
Thermostat
Heater
Heater
Heater
240/340 Indoor
Green LED
SV3
SV2
SV1
MV
IG
Flow
Adjust-
ment
Valve
Flow
Sensor
FM
240/340 Indoor Only
240/340 Indoor Only
Not
Used
For instructions on how to use checkpoints during troubleshooting, refer to the water heater’s maintenance