- 9 -
5-2. Receiver
1)Key function
Power ON / OFF
*Power save function: Automatically power off after 5 minutes of inactivity.
Adjusts Signal sensitivity for PEAK MODE.
Depth measurement
:
Press
DEPTH
key at the peak value spot.
Battery
compartment
Earphone plug
Signal input terminal
(8-pin connector)
Depth
Current index : Details page 25
Note: Current index is not displayed if probe is used.
Frequency
Receiving sensitivity
100% - 100%
30%
Magnetic
field
Gain Adjust Depth / Current Frequency
Note: 100% is not the maximum peak value. When 100% appears, press Gain key again
until a new sharp peak value is obtained, that is not 100%.
Bar-graph
Battery indication
Peak value spot = Top of the line
70%
50%
50%
Receiving sensitivity
Press GAIN key
20%
20%
30%
Press GAIN key
30%
Power Peak / Null Mode
Measuring Mode
RS232C
Connector
Power
Gain
Adjust
Depth /
Current
Null Mode
Peak Mode
Peak mode :Maximum sensitivity is the point directly
above the object line.
Null mode : Minimum sensitivity is the point directly above
the object line. The buried object line is
indicated with arrow.
Selects locating mode.
Peak / Null