Taifun®  LTB 

  User  Manual

 

 

 

 

 

 

 

 

 

 

2

 

 

IMPORTANT 

Please read these instructions carefully,  

before using your Taifun® LTB.  

 
 

 

 

Dear shopowner, 

Thank you for purchasing a Taifun® Liquid - Test - Bar (LTB). 
The  company 

SmokerStore

  has  worked  long  and  hard  on  this 

unit,  so  you  can  offer  your  customers  a  hygienical  way  to  test 
liquids. 

The unit is divided into a base unit (similar to a vaping device) 
and  10  rebuildable  atomizers.  These  are  10  Taifun®  GTII 
atomizers,  specially  modified  for  the  LTB,  similar  to  the 
atomizers that you already know. 

By  pushing  on  one  of  the  10  control  buttons,  the  respective 
atomizer is "activated" and vaporizes the liquid contained in it. 
A  durable,  maintenance-free  membrane  pump  inside  the  base 
unit accelerates the steam, so that the customers can inhale  it 
without contact to the atomizers. 

The  excellent  taste,  the  fast  and  hygienic  try  out  of  various 
liquids will delight your customers. 

 
Please mind the following instructions for handling the device 
and the possible health risks that may be caused by vaping.  
 

 

Summary of Contents for SmokerStore Liquid Test Bar

Page 1: ...Taifun GT II GT II Air Bedienungsanleitung deutsch User Manual english LTB...

Page 2: ...ese are 10 Taifun GTII atomizers specially modified for the LTB similar to the atomizers that you already know By pushing on one of the 10 control buttons the respective atomizer is activated and vapo...

Page 3: ...Taifun LTB during power on in delivery status 14 Status display and error display of the Taifun LTB during use 15 Further functions of the Taifun LTB 18 Turn on off keylock 18 Antitheft 18 Turn funct...

Page 4: ...r example youth protection has to be considered by the shop owner x The manufacturer cannot be held liable for any direct or indirect health damage resulting in use of the device or the use of liquids...

Page 5: ...been tested at the factory according to VDE 0701 0702 electrical safety testing x This test must be repeated each year to ensure user safety x The device is designed for a maximum working time of 12 h...

Page 6: ...the device or the power cord shows visible damage x the device contains loose parts noise from loose parts for example during transport x the device no longer works as intended x if the device has bee...

Page 7: ...g atomizers Fire and burn hazard x Do not use in areas which could be enriched with flammable gases vapors or dusts Risk of explosion x Never expose the device to rain moisture or humidity x Do not ex...

Page 8: ...onment temperature range 5 to 30 C non condensing x Storage temperature range 0 to 50 C x Output of about 19 watts x Adjustable voltage of 3 4 volts left to 4 6 Volts right clockwise applies to all 10...

Page 9: ...operation Kanthal or NiCr wire 1 00 0 1 U 4 4 Volt x Lack of liquid detection activated Dicodes temperature wire NiFe30 0 5 0 6 at room temperature U 4 0 Volt RECOMMENDATION OF THE MANUFACTURER We re...

Page 10: ...warranty case Only the failure of two or more LEDs is a valid warranty If you have any difficulties problems or questions please contact your dealer or the manufacturer The user manuals for the Taifun...

Page 11: ...the correct function of the sensor After a while a salt crust will form inside the chamber As long as the salt crust remains visible adding of further salt solution is not necessary Coil building see...

Page 12: ...e Then the Taifun LTB performs a self check LED Check 1 All 10 LED lights will briefly turn red LED Check 2 All 10 LED lights will briefly turn green Status display of functions The LED Pos 1 6 from l...

Page 13: ...ugh the selected atomizer without generating steam Generating steam Now steam is generated for a period of a maximum of 6 seconds The steam comes out on the upper side of the atomizer and can then be...

Page 14: ...an leaking atomizer standard green activated 2 Lack of liquid detection detects a dry wick standard red deactivated normal wire mode is active 3 Antitheft Alarm optional function standard red deactiva...

Page 15: ...ess button 5 times Status Description Single LED is GREEN Ready to use Valid atomizer detected Troubleshooting Status Description All LEDs are GREEN changing Stand By Mode After a few minutes the Taif...

Page 16: ...in Status Description Single LED flashes RED once per second Lack of liquid during vaping detected Only works with thermal wire NiFe30 Troubleshooting Refill the tank with liquid Then a reset is requi...

Page 17: ...ed atomizer or the anti theft protection alarm you can deactivate these functions of the Taifun LTB temporarily and continue operating with the remaining atomizers until completing troubleshooting ste...

Page 18: ...switch on the back the voltage can be adjusted 7 positions The lowest setting left is 3 4 volts the maximum setting right is 4 6 volts The maximum current is 5 amps Liquid detection It is required to...

Page 19: ...while holding the the corresponding key 1 6 IMPORTANT Between turn off and on again there should be a minimum of 5 sec waiting time to clear the memory During switching it is necessary to hold the cor...

Page 20: ...ss the button 6 and keep it pressed Step 3 With the other hand you turn the device back on Step 4 It starts with the initial LED check 1 and LED check 2 Then the LEDs pos 1 6 from left to right light...

Page 21: ...essed Step 3 With the other hand you turn the device back on Step 4 It starts with the initial LED check 1 and LED check 2 Then the LEDs pos 1 6 from left to right light up briefly and indicate the cu...

Page 22: ...led off upwards Step 3 Now the sealing ring can be removed Step 4 Unscrew the atomizer Step 5 Now you should check if liquid is in the connection chamber Step 6 If necessary remove the liquid using a...

Page 23: ...th Do not use abrasive sponges scouring agents acid solution or fatty cleaners or sharp objects for cleaning For stubborn dirt a lightly moistened cloth may be used with warm water and a mild househol...

Page 24: ...ers must not remain on the Taifun LTB during transport If you don t remove the atomizers it is possible that liquid will enter the air pipe Visual controll of the chambers Once the atomizers are remov...

Page 25: ...cing the fuse of the Taifun LTB Disconnect the Taifun LTB from the power source and pull the fuse on the rear out Now the fuse can be replaced Insert the new fuse Then the Taifun LTB can be connected...

Page 26: ...Omega Pic 8 Attach the chamber sleeve from the top Pic 9 Now push the chamber sleeve down until it clicks into place Pic 10 Guide the cotton through the coil Pic 11 Pull the chamber sleeve up until it...

Page 27: ...till holding the atomizer upside down IMPORTANT Do not overfill The capacity of each tank is about 5 ml Visual controll of the chambers Before you screw the atomizer back on the device you should insp...

Page 28: ...english Taifun LTB User Manual 28 SMOKERSTORE ELECTRONIC VAPING PRODUCTS SmokerStore GmbH www smokerstore de...