background image

FY-Series Digital PID Controller 

Operation Manual 

FY400            FY700          FY800                FY900                      FY600

48x48   

 

72X72   

  48X96   

 

  96X96   

 

 

  96X48 

(DIN 1/16)        (DIN 3/16)        (DIN 1/8)        

(DIN 1/4)               

(DIN 1/8)     

NOVEMBER,  2005 

FY_OPER_EN_V4 

GOLINK

OT1

OT2

AT

AL1

AL2

PRO

RESET

400

400

OUT1

OUT2

A T

AL1

AL2

AL3

MAN

PRO

OUT1

%

AUTO

RESET

GOLINK

0

20

40

60

80 100

800

800

OUT2

AL2

OUT1

A T

AL1

AL3

MAN

PRO

OUT1

%

AUTO

RESET

GOLINK

100

80

60

40

20

    0

600

600

GOLINK

OUT1

%

AUTO

RESET

OUT1 OUT2

A T

AL1

AL2

AL3

MAN

PRO

0

20

40

60

80

100

900

900

GOLINK

OUT1

OUT1 OUT2

A T

AL1

AL2

AL3

MAN

PRO

AUTO

RESET

%

0

20

40

60

80

100

700

700

Summary of Contents for FY series

Page 1: ...N_V4 GOLINK OT1 OT2 AT AL1 AL2 PRO RESET 400 400 OUT1 OUT2 AT AL1 AL2 AL3 MAN PRO OUT1 AUTO RESET GOLINK 0 20 40 60 80 100 800 800 OUT2 AL2 OUT1 AT AL1 AL3 MAN PRO OUT1 AUTO RESET GOLINK 100 80 60 40 20 0 600 600 GOLINK OUT1 AUTO RESET OUT1 OUT2 AT AL1 AL2 AL3 MAN PRO 0 20 40 60 80 100 900 900 GOLINK OUT1 OUT1 OUT2 AT AL1 AL2 AL3 MAN PRO AUTO RESET 0 20 40 60 80 100 700 700 ...

Page 2: ...eration levels 7 1 Levels diagram Page 16 7 2 Lock function Page 16 8 Parameters 8 1 Level 1 User Level Page 17 8 2 Level 2 PID Level 8 2 1 Level 2 parameters display hiding condition Page 18 8 2 2 Description of parameters Page 19 8 3 Level 3 Input Level Page 20 8 4 Level 4 SET Level 8 4 1 How to hide parameters Use SET1 SET7 Page 22 8 4 2 Special functions Use SET8 SET9 SET0 Page 23 8 4 3 Remote...

Page 3: ...age 37 17 2 TTL Communication SV output and RATE function Page 38 17 3 1ψ Phase angle control By SCR module Page 39 17 4 1ψPhase angle control By TRIAC Page 40 17 5 3ψPhase angle control By DIODE SCR module Page 41 17 6 1ψZero crossing control By SCR Module Page 42 17 7 1ψZero crossing control By TRIAC Page 43 17 8 3ψZero crossing control By SCR module Page 44 17 9 3ψZero crossing control By TRIAC...

Page 4: ...00 with Pin 1 and 2 2 Be sure to use the rated power supply AC85 265V or DC24V otherwise it would be caused aggravated damage on controller 3 Please confirm wires are connected with correct terminal Input Output 4 Use M3 screw compatible crimp on terminals with an insulation sleeve as shown below 3 2mm 3 2mm Torque 0 4 N m 4kgf cm 5 Avoid installing controller in following spaces I A place where t...

Page 5: ...For SSR drive ON 24V OFF 0V max load current 20mA mA dc 4 20mA 0 20mA Maximum load resistance 560 Ω Output 1 Voltage dc 0 5V 0 10V 1 5V 2 10V Max load current 20mA Alarm 1 3A 220V electrical life 100 000 times or more under rated load Control algorithm PID PI PD P ON OFF P 0 FUZZY PID range P 0 0 200 0 I 0 3600s D 0 900s Isolation Output terminals control output alarm transmission and input termin...

Page 6: ...4 20mA 0 20mA 0 1V 0 5V 0 10V 1 5V 2 10V Remote SV 4 20mA 0 20mA 0 1V 0 5V 0 10V 1 5V 2 10V Protocol MODBUS RTU MODBUS ASCII TAIE RS232 RS485 TTL Communication Baud rate 2400 4800 9600 19200 38400 bps Data bits 8 Stop bit 1 or 2bit Odd or Even parity Water Dust proof IP65 z Special control output OUT1 Model FY400 FY600 FY700 FY800 FY900 1φ zero crossing control 1φSSR Available Not available Availa...

Page 7: ...ΦZero Cross Control Relay SSR mA V OUT2 2 3 CLOSE OPEN COM OUT1 Proportional Motor Valve Control B Control Output mA V RTD TC mV C Input 2 3 AL 1 11 12 AL 1 13 14 AL 2 D Alarm TRS E Transmission RS232 F Communication 11 12 13 RD SD SG RS485 11 12 Dx Dx TTL 11 12 13 RD SD SG Option Use OUT1 OUT2 Proportional Motor Valve Control H CT Input CT 11 12 ...

Page 8: ...PEN OUT1 Proportional Motor Valve Control B Control Output mA V RTD TC mV C Input AL 1 6 7 AL 2 D Alarm TRS E Transmission RS232 G Communication 14 15 16 RD SD SG RS485 14 15 Dx Dx TTL 14 15 16 RD SD SG Option 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 7 8 9 10 COM 6 7 8 9 10 17 18 19 20 17 18 19 20 17 18 19 20 AL 3 12 13 Remote SV F Remote 14 15 H CT Input CT 14 15 ...

Page 9: ...ntrol Output mA V RTD TC mV C Input 3 4 AL 2 D Alarm TRS E Transmission RS232 G Communication 15 16 17 RD SD SG RS485 15 16 Dx Dx TTL 15 16 17 RD SD SG Option COM 3 4 5 6 7 11 12 13 14 11 12 13 14 11 12 13 14 AL 1 18 19 Remote SV F Remote 9 10 5 6 7 21 15 16 17 18 20 PROT G1 G2 OUT1 20 15 17 19 PROT 8 9 10 COM NO NC Proportional Motor Valve Control 1ΦZero Cross Control 1ΦPhase Angle Control H CT I...

Page 10: ...PEN OUT1 Proportional Motor Valve Control B Control Output mA V RTD TC mV C Input AL 1 6 7 AL 2 D Alarm TRS E Transmission RS232 G Communication 14 15 16 RD SD SG RS485 14 15 Dx Dx TTL 14 15 16 RD SD SG Option 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 7 8 9 10 COM 6 7 8 9 10 17 18 19 20 17 18 19 20 17 18 19 20 AL 3 12 13 Remote SV F Remote 14 15 H CT Input CT 14 15 ...

Page 11: ... 27 28 29 30 17 18 19 20 17 18 19 20 17 18 19 20 AL 3 39 40 Remote SV F Remote 14 15 G1 G2 OUT1 1ΦZero Cross Control 40 31 33 39 PROT G1 K1 G2 K2 OUT1 1ΦPhase Angle Control CLOSE OPEN OUT1 COM 6 7 8 9 10 36 31 32 33 34 35 PROT RG1 RG2 TG1 TG2 OUT1 3ΦZero Cross Control 40 31 33 35 37 39 PROT G1 K1 G2 K2 OUT1 3ΦPhase Angle Control 40 31 32 33 34 39 PROT G3 K3 35 36 RS232 31 32 33 RD SD SG RS485 31 3...

Page 12: ...96 96 90 5 0 5 90 5 0 5 111 116 GOLINK OT1 OT2 AT AL1 AL2 PRO RESET 400 400 OUT1 OUT2 AT AL1 AL2 AL3 MAN PRO OUT1 AUTO RESET GOLINK 0 20 40 60 80 100 800 800 OUT2 AL2 OUT1 AT AL1 AL3 MAN PRO OUT1 AUTO RESET GOLINK 100 80 60 40 20 0 600 600 GOLINK OUT1 AUTO RESET OUT1 OUT2 AT AL1 AL2 AL3 MAN PRO 0 20 40 60 80 100 900 900 GOLINK OUT1 OUT1 OUT2 AT AL1 AL2 AL3 MAN PRO AUTO RESET 0 20 40 60 80 100 700 ...

Page 13: ...gs are changed 6 6 Down key Program hold Decrease numbers 1000 100 10 1 Program hold Programmable controller 7 7 Up key Program run Decrease numbers 1000 100 10 1 Program run Programmable controller OUT1 8 8 OUT1 lamp Lights when OUT1 is activated Green OUT2 9 9 OUT2 lamp Lights when OUT2 is activated Green AT 1 10 0 Auto tuning lamp Lights when Auto tuning is activated Orange AL1 1 11 1 Alarm 1 l...

Page 14: ...2 AT AL1 AL2 AL3 MAN PRO AUTO RESET 0 20 40 60 80 100 GOLINK OUT1 OUT1 OUT2 AT AL1 AL2 AL3 MAN PRO AUTO RESET 0 20 40 60 80 100 13 6 Operations 6 1 Power On Controller will display as below Display input type K2 Display range 0 0 400 0 Ready for use displays will be lighted 6 2 Change the Set Value SV Change SV from 0 0 to 100 0 Press key The SV number started to flash The flashing digit indicates...

Page 15: ...ey to change AT setting Press key change AT to YES Press key Start auto tuning AT lamp will be lighted on OFF ON ON OFF ON OFF Control Autotuning PID Control After Autotuning SV PV 0 100 Output Autotuning ATVL 0 OFF ON ON OFF SV PV 0 100 Autotuning ATVL 20 SV 20 Autotuning failure Overshoot Set ATVL to prevent overshoot occurred during autotuning process Output ON OFF Control Autotuning PID Contro...

Page 16: ...OUT1 OUT2 AT AL1 AL2 AL3 MAN PRO AUTO RESET 0 20 40 60 80 100 GOLINK OUT1 OUT1 OUT2 AT AL1 AL2 AL3 MAN PRO AUTO RESET 0 20 40 60 80 100 GOLINK OUT1 OUT1 OUT2 AT AL1 AL2 AL3 MAN PRO AUTO RESET 0 20 40 60 80 100 GOLINK OUT1 OUT1 OUT2 AT AL1 AL2 AL3 MAN PRO AUTO RESET 0 20 40 60 80 100 15 6 5 Programmable RAMP SOAK Only available for PFY model For detail of the programmable instruction please refer w...

Page 17: ... In any Level press key twice will return to Level 1 Level 4 SET Level Press Key 5 seconds LCK 1111 Press Key 5 seconds 7 2 Lock function To use lock function please set parameter LCK in level 2 Levels entering available LCK Level 1 User Level 2 PID Level 3 Input Level 4 SET Parameters which can be changed All parameters Factory set value All parameters All parameters except level 3 Parameters in ...

Page 18: ...ameters 8 1 Level 1 User Level Process Value Set Value Output Limt Autotuning Alarm 1 set value Alarm 2 set value Alarm 3 set value PV SV Heater current display HBA set value RESET RESET RESET RESET RESET RESET ...

Page 19: ...output P1 Single output P1 1 Press key 5 seconds to enter level 2 2 Set LCK to 1111 3 Press key and key 5 seconds to enter level 4 Set level 4 Set OUTY to 1 Dual output P1 P2 Dual output P1 P2 RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RESET RES...

Page 20: ... USPL Range 0 150 seconds Relay output 10 Voltage pulse output 1 mA output 0 Range 0 1000 The same with P1 The same with I1 The same with D1 The same with CYT1 The same with HYS1 Set point of output 1 Heating side SV GAP1 SV GAP2 Return to P1 If P2 0 0 Display d e d i v o r p s i 2 t u p t u o f i y a l p s i D Integral time 1 For output 1 Derivative time 1 For output 1 If P1 0 0 Display Levels en...

Reviews: