Chapter 5 System connection and basic setup procedure
5.1 System connection
HCS-8600 series fully digital congress system has a
simple and reasonable structure with high extendibility in
hardware. The system installation is simple and quick
and does not need special training. Daisy-chain
connection is adopted between congress units as well as
to CMU via dedicated 8-pin cable or converter cable.
TCP/IP protocol is adopted for Ethernet connection
between CMU and PC. As a result remote control,
remote diagnosis and remote update can be achieved.
Application software for client and server can run on one
computer or on different computers in the same LAN.
The operator is able to control the progress of the
meeting flexibly.
In this chapter, the connections of HCS-8600 series fully
digital congress system are introduced by diagrams and
examples.
5.1.1 Connection principles
In HCS-8600 series fully digital congress system, power
is provided
by
HCS-8600M
CMU
(EMU)
or
HCS-8600EMS
for all congress
units
(except
HCS-8668/8638/8665 series congress terminals). Thus,
the total number of system units in any installation is
limited by the maximum power handling capacity and
control capacity of the HCS-8600M CMU (EMU) or
HCS-8600EMS. It must be ensured that, during the
installation, the sum of the total power consumption of all
the congress units connected to every single 8P-DIN
interface plus the power loss in the extension cables
does not surpass the power limit of each 8P-DIN
interface. Otherwise the system will not work properly or
automatic protection will occur. Refer to table 5.1.1for
maximum load capability.
HCS-8668/8638/8665 series congress terminals are
provided power by HCS-8600KMX or HCS-8600POE.
When power is supplied on PoE mode, the number of
terminals can be expanded through HCS-8368 (T/50).
Refer to table 5.1.2 and table 5.1.3 for maximum load
capability.
By cascade connecting extension main units
(HCS-8600MEA series) or extension units
(HCS-8600MES),
the
HCS-8600
system can
accommodate 4096 discussion/voting units (by using
system application software up to 100 chairman units
can be connected but only 1 chairman unit has control
facilities), 378 interpreter units (63 interpreter booths, 6
in each), an unlimited quantity of channel selectors, and
provide 64 language channels (including floor language)
simultaneous interpretation.
Note:
The added up cable lengths between a main
unit and the most remote congress unit must
not exceed 250 m;
The length of an individual extension cable
must not exceed 80 meters. Otherwise it will
affect the signal quality. In case the length
exceeds 80 m, HCS-4852T(N) is needed; The
length of an individual extension cable
following HCS-4852T(N) must not exceed 80
meters;
Normally, when the extension cable is less
than 60 meters, it is recommended to use a
cat5e cable with drain wire; when the
extension cable is longer than 60 meters,
please be sure to replace the cat5e cable with
braided shield;
The extension cable between the main
unit/extension unit and the first congress unit
is carrying the maximum possible current.
However, the cable length between the two
last congress units is nearly insignificant
because this cable only carries the current for
one unit.
111
Summary of Contents for HCS-8600 Series
Page 1: ...Paperless Multimedia Congress System Installation and Operating Manual V 1 0...
Page 14: ...Figure 1 1 4 HCS 8668 Series Paperless Multimedia Congress System connection diagram 3...
Page 91: ...3 3 2 Fixed installation Figure 3 3 2 Fixed installation of HCS 8665 series congress unit 80...
Page 109: ...4 1 Functions and indications Front Side Bottom Figure 4 1 HCS 8685 Interpreter unit 98...
Page 118: ...Blue 107...
Page 145: ...Figure 6 2 3 HCS 8668 Series Paperless Multimedia Congress System connection diagram POE 134...
Page 180: ...Appendices Custom made cables Appendix Ethernet Cable 169...
Page 181: ...Appendix CBL4PK 01 Power Adapter Cable 170...
Page 182: ...Appendix CBL4PT 02 Power Branch Cable 171...