3.5.2 Installation of HCS-5300TDS/80
①
M6×60 hook up riveting bolt
②
M4 screw
(
M4×40
)
and nut
③
User customized suspension (see figure 3.30 for requirements) or HCS-5300TDP suspension (optional length)
④
M3×12 screw
⑤
Hard ceiling (such as concrete ceiling)
Figure 3.27 HCS-5300TDS/80 digital infrared transceiver suspension mounted
Mounting steps:
Step 1:
Fix M6×60 hook up riveting bolt onto the hard ceiling (such as concrete ceiling);
Step 2:
Fix HCS-5300TDS/80 digital infrared transceiver onto the suspension with M3×12
screws;
Step 3:
Pull the M4 screw over the mounting hole at the top of the
suspension and fix it
with M4 nut;
Step 4:
Hang the suspension on M6 hook up riveting bolt.
WARNING:
This installation method is applicable to hard ceiling (such as concrete ceiling),
and when the thickness of the ceiling is greater than the length of M6 screw.