2.4.4 To interpreter unit
Interpreter units
(
HCS-4385U/50 or HCS-8385/80
)
can be connected to the interpreter’s unit interface of
HCS-5100MA/F. It must be ensured that, during the
installation, the sum of the total power consumption of
all the interpreter units connected to the 6P-DIN
interface plus the power loss in the extension cables
does not surpass the power limit of the 6P-DIN
interface. Otherwise the system will not work properly
or automatic protection will occur (see table 2.1).
Figure 2.7 Transmitter connected to interpreter units
2.4.5 To HCS-8300 Paperless Multi-media
Congress System
HCS-5100MA/F
connected to
HCS-8300
Paperless Multi-media Congress System
HCS-8300M congress main unit can be connected via
optical fiber interface (HCS-5100MA/FS/F), 6P-DIN
interface or DCS interface on HCS-5100MA/F, and 4, 8
or 16 channels audio output can be used for audio
recording (see figure 2.8).
HCS-5100MC/F
connected to
HCS-8300
Paperless Multi-media Congress System
HCS-5100MC/F transmitter do not have optical fiber
interface, 6P-DIN interface or DCS interface, it can be
connected to TAIDEN HCS-8300M congress main unit
through TAIDEN HCS-8300MO 8 Channels Audio
Output Device. The output of HCS-8300MO should be
connected to the audio input of HCS-5100MC/F
transmitter one-to-one correspondingly through audio
cable (see figure 2.9).
Table 2.1 Quick lookup table for the max. number of interpreter units
(
unit
:
pcs
)
Type No.
The extension cable length between the CMU and the first interpreter Unit
connected to the socket
20 m
40 m
60 m
80 m
HCS-4385U
14
11
8
6
HCS-8385
9
7
5
4
*
Note:
Cable Splitter HCS-4352T is needed when the length of an extension cable exceeds 80 m.
(Cable splitter is used as repeater only and cannot improve load capability.)