Tador Technologies Doorphone User guide
1
General:
The Doorphone unit is an intelligent telephone connected
to a telephone exchange, mounted on office entrance and
enables visitors to call to a predefined extension.
Person receiving a call from the door panel can speak with the visitor
and open the door from his telephone extension by pressing a
particular key.
Open the door from the inside is possible by pressing
a bypass pushbutton.
Features:
Easy installation, programming and
operating.
Power failure resistance, keeps the
programmable values in nonvolatile memory.
Controls a safety camera.
Can be programmed from any extension.
Programmable extension key to open door
Ability to control 2 entrance doors instead of
the camera.
Every extension can open the door by
pressing a key.
optional bypass exit pushbutton
Anti vandal resistance.
Specifications:
Operating voltage: AC 12V 1000mA
Opening time: 1-99 seconds
Operating electric or magnetic lock. (normally
open or normally close)
Size: under plaster 195X115X50mm (H*W*D)
On the wall 154X100X35mm (H*W*D)
Color: silver or bronze
Installation:
According to the door lock type,3 pins connector JM1 should be set
Desirable DOOR state when entering valid code
Jumper JM1
Close circuit (Normally open) for electric lock
Jumper on 2 left pins (default
state)
Open circuit (Normally close) for magnetic lock
One Jumper on 2 right pins
After installing the lock in the door frame. Route the following wirings to the Doorphone:
1.
2 wires from power supply.
2.
2 wires from the lock.
3.
2 wires from a telephone exchange free extension.
4.
2 wires from optional bypass pushbutton.
Using Phillips screw driver open 4 top cover’s screws, carefully pull up the panel.
Using a screw driver, expose the 4 covered insulations bores and the round wirings bore.
Attach the base of the Doorphone to the wall, using a pencil mark the 4 fixing points.
Drill the 4 fixing points on the wall.
Route the wires through the round bore in the base of the Doorphone.
Using 4 screws install the base to the wall.
Verify the power supply is not connected to power source!
Connect the wires to circuit board terminals according to the circuit’s labels, the attached
electrical diagram and the following instructions.
Connect: Power supply to the two 12VAC terminals.
To connect an electric lock: One wire from the lock to the RELAY terminal. The second wire
from the lock to one of 12VAC terminals. Short wire from the second 12VAC terminal to the
second RELAY terminal.
(the RELAY functions as a switch)
If you intend to install a bypass pushbutton, connect it between RMT terminal and the +V
terminal.
2 wires from telephone exchange free extension to LINE.
the polarity of the wires is non significant.