Viessmann KM-Bus installation complete
1. Test the system
2. Hand over the registration card to the customer
6. Heating System Settings
For the heating circuit controlled by tado°, set the same settings as for a
Viessmann Vitotrol 200 remote control.
Controller
Heating System Settings
Vitotronic 200 GW..
Vitotronic 300 GW..
Vitotronic 200 HO..
Vitotronic 200 KW..
Vitotronic 300 KW..
Vitotronic 200 KO..
90: Time constant for calculating
the adjusted outside temperature 12
A0: Remote Control
1 (If 1 can not be selected,
use 2)
b0: Room Temperature
Hook-up
3
b2: Room Influence Factor
64 (If 64 can not be selec-
ted, use 31)
b5: Heating Circuit Pump Logic 5 (If 5 can not be selected,
use 1)
FA: Increase of the set flow
temperature
0
Viessmann
KM-Bus
29