59
9-2 Common Parameters
1
.
Display error code of indoor unit: Frequency conversion air conditioners only
involve E1, E2, E3 and E4
No.
Error
Code
Error Name
Probable Trouble Location
1
E1
Internal room temperature
sensor error
Internal room temperature sensor, main
internal control panel
2
E2
External coil sensor error
External coil sensor error, main external
control panel
3
E3
Internal coil sensor error
Internal coil sensor error, main internal
control panel
4
E4
Indoor fan error
Mechanical jam of internal fan blade,
internal fan, main internal control panel
5
E5(5E)
Indoor and outdoor unit
communication error
Bridge cable, main internal control panel,
main external control panel, module panel
6
F0
Outdoor DC fan error
Mechanical jam of external fan, external
DC fan, main external control panel
7
F1
Module protection error
Power voltage, compressor cable, reactor,
module panel, main external control panel,
compressor
8
F2
PFC protection error
Power voltage, reactor, module panel, main
external control panel
9
F3
Compressor out-of-step
error
System pressure, compressor cable,
module panel, main external control panel,
compressor
10
F4
Exhaust air sensor error
Exhaust air sensor, main external control
panel
11
F5
Compressor cap sensor
error
System pressure, compressor cap sensor
(protection switch), main external control
panel
12
F6
External room temperature
sensor error
External room temperature sensor, main
external control panel
13
F7
OVP or UVP error
Power voltage, reactor, module panel, main
external control panel
14
F8
Main external control
panel and module panel
communication error
Connection wire of module and main
control data, module panel, main external
control panel
15
F9
Outdoor EE error
Main external control panel
16
FA
Recirculated sensor error
Recirculated sensor, four-way valve, main
external control panel
Summary of Contents for Swift Inverter 9U
Page 1: ...Swift Inverter Split Type Air Conditioner...
Page 3: ...1 Part I Technical Information 1 Summary 1 1 Appearance Indoor Unit...
Page 4: ...2 Outdoor Unit 9K 12K 18K 24K 36K Note The outdoor grille can be replaced...
Page 28: ...27 Part II Installation and Maintenance 7 Main Tools for Installation and Maintenance...
Page 69: ...68 Remote Control Can Not Work Trouble shooting procedure...
Page 92: ...91 2 Swift Inverter 12U Exploded View...
Page 94: ...93 3 Swift Inverter 18U Exploded View...
Page 96: ...95 4 Swift Inverter 24U Exploded View...
Page 98: ...97 11 2 Outdoor Unit 1 Swift Inverter 9U Exploded View...
Page 100: ...99 2 Swift Inverter 12U Exploded View...
Page 102: ...101 3 Swift Inverter 18U Swift Inverter 24U Exploded View...