![Tadiran Telecom Swift Inverter 9U Service Manual Download Page 38](http://html1.mh-extra.com/html/tadiran-telecom/swift-inverter-9u/swift-inverter-9u_service-manual_3260285038.webp)
37
9. Maintenance
9-1 Troubleshooting Guide
Many error codes many appears on this air conditionor, and this troubleshooting
guide is prepared for the maintenance personnel to detect the error position and the
parts to be replaced during the troubleshooting process. In this Guide, the
Troubleshooting Method is guided by the Error Name, and the Reference Code under
the General Index is the error code of the internal unit of the mainstream model
supplied by the Company.
Example:
“internal coil sensor error” is coded as E3 in the error code of the internal
unit, but appears as flash-out via the trouble light of the external machine. However,
their troubleshooting method is the same, and use the same table as well.
General index:
No.
Error Name
Reference Code
1
Internal temperature sensor error
E1
2
External coil sensor error
E2
3
Internal coil sensor error
E3
4
Internal fan error of
wall mounted air
conditioner
(
PG motor
)
E4
5
Internal fan error of
wall mounted air
conditioner
(
DC motor
)
E4
6
Sliding door error of floor standing
E4
7
Internal and external communication error
E5
(
5E
)
8
External DC fan error (3-core terminal motor)
F0
9
Module protection error
F1
10
PFC protection error
F2
11
Compressor startup error
F3
12
Exhaust sensor error
F4
13
Pressing top head sensor error
F5
14
External temperature sensor error
F6
15
OVP or UVP error
F7
16
Main external control panel and module panel
communication error
F8
17
Outdoor EE error
F9
18
Recirculated sensor error
(
four-way valve switch
error
)
FA
19
Cabinet internal fan error (see E4 for
troubleshooting)
Fb
20
Function protection prompt of frequency
conversion external machine
See the Error List
Summary of Contents for Swift Inverter 9U
Page 1: ...Swift Inverter Split Type Air Conditioner...
Page 3: ...1 Part I Technical Information 1 Summary 1 1 Appearance Indoor Unit...
Page 4: ...2 Outdoor Unit 9K 12K 18K 24K 36K Note The outdoor grille can be replaced...
Page 28: ...27 Part II Installation and Maintenance 7 Main Tools for Installation and Maintenance...
Page 69: ...68 Remote Control Can Not Work Trouble shooting procedure...
Page 92: ...91 2 Swift Inverter 12U Exploded View...
Page 94: ...93 3 Swift Inverter 18U Exploded View...
Page 96: ...95 4 Swift Inverter 24U Exploded View...
Page 98: ...97 11 2 Outdoor Unit 1 Swift Inverter 9U Exploded View...
Page 100: ...99 2 Swift Inverter 12U Exploded View...
Page 102: ...101 3 Swift Inverter 18U Swift Inverter 24U Exploded View...