Coral Terminal Equipment
2-9
Fle
xSet T
roubles
hooting
2
.
If a FlexSet is wired up as a PF station to a 4T-C, 8T-C, 4T-CID, 8T-CID, 4T-C Office,
8T-C Office, 4T-CID Office, 8T-CID Office, 4T-Cipx, 8T-Cipx, 4TMR-PF, 4TPF, 8TPF,
4ALS or 8ALS circuit, one or more of the following undesirable results may be
obtained.
1.
The FlexSet will not work in PF mode.
2.
The FlexSet will be ruined by incoming ring voltage on the PF trunk.
3.
When the Coral resets and comes back on-line, the FlexSets wired for power fail
operation will never initialize, because the Coral will sense the PF Trunk as
activated and not reset the trunk or FlexSet.
6
Power Failure Mode
FlexSets cannot be used as power failure stations. The FlexSet is a digital instrument
and cannot be used in a Power Failure connection. It will be ruined by incoming ring
voltage on the PF trunk.
Summary of Contents for FlexSet 280
Page 62: ...4 6 Coral Terminal Equipment FlexSet PEX F PEX FS Installation 4 NOTES...
Page 80: ...6 8 Coral Terminal Equipment FlexSet PEX APA F PEX APA FS Installation 6 NOTES...
Page 110: ...9 10 Coral Terminal Equipment FlexAPDL Installation 9 NOTES...
Page 124: ...10 14 Coral Terminal Equipment CPA Installation 10 NOTES...
Page 126: ...11 2 Coral Terminal Equipment VoIP Terminals 11 NOTES...
Page 128: ...12 2 Coral Terminal Equipment DKT DST DPEM Terminals Keyset Installation 12 NOTES...
Page 130: ...13 2 Coral Terminal Equipment FlexAir CoralAIR Wireless Handset Handset Installation 13 NOTES...
Page 131: ......