Sentinel Pro Installation Procedure and Reference Manual
- for Coral IPx / FlexiCom
Troubleshooting
53
Power Supply Failures
8
8
Troubleshooting
The procedures described in this chapter are intended for troubleshooting and repair
purposes and should be performed with the necessary precautions.
................................................................................................................
Power Supply Failures
Power supply failure generally results in the loss of one or more output voltages.
However, protection circuitry in the power supply regulator may shut down a regulator
due to a current overload caused by an external fault.
If the power switch on the Sentinel Pro rear panel is turned ON and the POWER LED
indicator on the front panel does not light, check the following:
1
Power cable not intact or disconnected. Connect the cable as described in
2
AC power failure
3
Blown main or circuit fuse/breaker in the building electrical panel
4
Blown fuse within the Sentinel Pro unit. Replace the fuse as described in
Replacing the Fuse in a Sentinel Pro Unit