Common Control Cards
8-23
MCB Office Car
d Ma
in
Contr
ol Boar
d
8
0
A new lithium battery can maintain power to the MCB Office memory circuitry and
real-time clock for approximately 90 days. The battery is
not
recharged by the system
power. Thus, if the battery has powered the memory and real-time clock for an
extended period and is almost discharged, the contents of the memory must be backed
up, and the battery must be replaced.
The battery voltage, tested under load, can be used to determine its state of charge.
Voltage measured across an unused battery connected to the memory circuitry should
fall between 3.30 and 3.35 volts. If the voltage measured across a battery is less than
2.50 volts, the battery must be replaced.
Replacing the Lithium Battery
In the following procedure, do not apply too much pressure to the battery clasp as this
could cause it to break.
1.
Turn off the battery switch.
2.
Carefully raise the battery clasp.
3.
Insert the new battery with the + (positive) symbol appearing on top.
4.
Turn on the battery switch.
...................................................................................................
7
Lithium Battery Condition Testing
Do not use any metal tool to release or insert the battery. Doing so could result in a
short circuit and damage the battery.
Explosion and Environmental Hazards.
There is a danger of explosion if the battery is replaced incorrectly.
Replace the battery only with the same or equivalent type recommended by the
manufacturer.
Dispose of used batteries according to requirements specified by the battery
manufacturer and/or local regulatory agencies.
Summary of Contents for Coral IPx Office
Page 2: ......
Page 4: ......
Page 25: ...xxi Figure 11 10 WiFi Antenna Removal 11 18...
Page 26: ......
Page 28: ......
Page 36: ...1 8 Introduction Coral IPx Office Installation Manual About this Manual 1 NOTES...
Page 44: ......
Page 96: ......
Page 106: ...3 10 Initial Power up Tests Coral IPx Office Installation Manual Common Control Test 3 NOTES...
Page 122: ......
Page 138: ......
Page 182: ......
Page 234: ......
Page 258: ...7 24 Power Supply Coral IPx Office Installation Manual PS Office DC Power Supply Unit 7 NOTES...
Page 260: ......
Page 302: ...8 42 Common Control Cards Coral IPx Office Installation Manual Compact Flash Disk 8 NOTES...
Page 310: ...8 50 Common Control Cards Coral IPx Office Installation Manual DBM Card 8 NOTES...
Page 312: ......
Page 372: ...9 60 Shared Service Cards Coral IPx Office Installation Manual VoIP Media Gateway MG 9 NOTES...
Page 420: ......
Page 488: ......
Page 509: ......