8-10
Coral IPx 500 Installation Manual
MC
P-IPx Car
d
Main Pr
ocess
o
r Unit
8
0
Figure 8-3
illustrates the front panel of the MCP-IPx card. The front panel contains various
elements. The following table is a listing of the various functions and what they are for.
Table 8-1
MCP-IPx
Control Card Functions
3
Front Panel Features
Function
What is it for?
Option DIP switches All switch should be set to OFF (right) so that the system will respond
after a power failure.
Status Display
7-segment display, used for alarms and diagnostic functions. A full list
of possible displays is provided later on in this chapter. See
page 8-20,
MCP-IPx Status Display Codes
.
Green LED
Lit on to indicate normal system operation.
RST - CPU Reset
Push Button
Forces the Coral system to restart.
Used to partially initialize the system (cause a
warm restart
procedure),
simulating the procedure that occurs automatically when power is
applied to the system.
Forcing initialization by pressing RST immediately disconnects all calls
in progress but does not default the database. However, resetting the
Main Processor while the database is being programmed, may corrupt
the database. If this happens, the database must be restored.
Pressing the RST button will cause a partial initialization.
All calls in progress will be terminated.
IMC8 Release
Button
Used to release the IMC8 card.
IMC8 Flash Memory
card
Used to save and restore the database as well as to store the Generic
feature software.
KB0
Data Terminal Port, DTE Interface, used to connect an RS232-E serial
cable, providing access to the PI or CoralVIEW CVA/CVD/CVT.
Default configuration:
9600 bps, No parity, 8 data bits, 1 stop bit, VT-100. See
page 8-13,
KB0 RS-232E Programming Port
.
Summary of Contents for Coral IPx 500
Page 22: ......
Page 26: ......
Page 28: ......
Page 42: ......
Page 58: ...2 16 Coral IPx 500 Installation Manual Site Inspection 2 NOTES...
Page 120: ......
Page 126: ...3 6 Coral IPx 500 Installation Manual Power Supply Test 3 NOTES...
Page 152: ...3 32 Coral IPx 500 Installation Manual Installation Wrap up 3 NOTES...
Page 154: ......
Page 170: ......
Page 184: ...5 14 Coral IPx 500 Installation Manual Protection Devices 5 NOTES...
Page 188: ...5 18 Coral IPx 500 Installation Manual Power Fail PF Transfer Circuits 5 NOTES...
Page 204: ...5 34 Coral IPx 500 Installation Manual MDFipx Units Supplied by the Manufacturer 5 NOTES...
Page 256: ......
Page 288: ...6 32 Coral IPx 500 Installation Manual Coral IPx 500M Main Cage Description 6 NOTES...
Page 296: ...6 40 Coral IPx 500 Installation Manual Coral IPx 500X Expansion Cage Description 6 NOTES...
Page 316: ......
Page 332: ...7 16 Coral IPx 500 Installation Manual PS500 DC Power Supply Unit 7 NOTES...
Page 350: ...7 34 Coral IPx 500 Installation Manual PS500 AC Power Supply Unit 7 NOTES...
Page 376: ......
Page 380: ...8 4 Coral IPx 500 Installation Manual Control Cards 8 NOTES...
Page 404: ...8 28 Coral IPx 500 Installation Manual IMC8 Card Flash Erasable Software Memory Unit 8 NOTES...
Page 412: ...8 36 Coral IPx 500 Installation Manual DBX Card Database Expansion Memory Unit 8 NOTES...
Page 426: ...8 50 Coral IPx 500 Installation Manual CLA Card CoraLINK Adapter 8 NOTES...
Page 428: ......
Page 432: ...9 4 Coral IPx 500 Installation Manual Shared Service Circuitry Installation 9 NOTES...
Page 460: ...9 32 Coral IPx 500 Installation Manual Three Way Conference Conference Circuitry 9 NOTES...
Page 490: ...9 62 Coral IPx 500 Installation Manual KB1 KB2 KB3 RS 232E Data Serial Port 9 NOTES...
Page 498: ...9 70 Coral IPx 500 Installation Manual Music Background and Music On Hold M1 M2 9 NOTES...
Page 518: ...9 90 Coral IPx 500 Installation Manual Relay Contacts RLY1 RLY2 RLY3 9 NOTES...
Page 520: ......
Page 526: ...10 6 Coral IPx 500 Installation Manual Peripheral Card Installation 10 NOTES...
Page 543: ......